-7-
TDK-Lambda
HWS1000 Series
INSTRUCTION MANUAL
2-5. Remote ON/OFF control required
2-6. PF signal output required
①
Remove standard attached connector, and use the harness
made by the customer and connect external signal to between
CNT and TOG terminal.
②
“TOG” terminal is ground for “CNT” terminal.
In case this function is not used, please short between
CNT and TOG terminal.
①
PF signal is an open collector output, therefore
PF signal outputs are shown in circuit below.
②
“TOG” terminal is ground for “PF” terminal.
Connecting circuit with CN01 or CN02 connector
Connecting circuit with CN01 or CN02 connector
1
3
5
7
9
11
2
4
6
8
10
12
1
3
5
7
9
11
2
4
6
8
10
12
M8 Bolts and nuts for connecting
to the load line
(These are not
attached
to the
product.)
Connector : (JST) S12B-PHDSS
Remove standard attached connector, and use the harness made by
the customer.
・
Housing : (JST) PHDR-12VS
・
Contact : (JST) SPHD-001T-P0.5
1
-
2, 3
-
4, 7
-
8
:
should be shorted
9
:
CNT
Should be connected to ON/OFF control signal.
10
:
TOG
Should be connected to Signal Ground.
* Please use wire for contact and crimping tool specified by maker.
M8 Bolts and nuts for connecting
to the load line
(These are not
attached
to the
product.)
Connector : (JST) S12B-PHDSS
Remove standard attached connector, and use the harness made by
the customer.
・
Housing : (JST) PHDR-12VS
・
Contact : (JST) SPHD-001T-P0.5
1
-
2, 3
-
4, 7
-
8, 9
-
10
:
should be shorted.
11
:
PF
Should be connected to PF signal output
12
:
TOG
Should be connected to Signal Ground.
* Please use wire for contact and crimping tool specified by maker.
-
+
-
+
Load
Load
NAME PLATE
NAME PLATE
ON
PF signal output
To signal ground