background image

PAH300

350S24

-SERIES 

4

 

TDK-Lambda 

 

Explanations on Specifications 

 

1. Input Voltage Range 

  Input  voltage  range  for  PAH300

350S24  Series  is 

indicated below.   

 

Input Voltage Range : 18

36VDC 

 

  Basically

ripple  voltage  (Vrpl)  which  results  from 

rectification  and  filtering  of  commercial  AC  line  is 
included  within  the  input  voltage  as  shown  in  fig.  1-1. 
Ripple  voltage  must  be  limited  within  the  voltage 
described below. 

 

Allowable input ripple voltage : 2Vp-p 

 
  When this value is exceeded, the output ripple voltage 
becomes large. 

  Note  that  sudden  input  voltage  change  may  cause 
variation of output voltage transitionally.   

  Also,  input  voltage  waveform  peak  value  must  not 
exceed above input voltage range.   

 

 

Fig.1-1 Input Ripple Voltage 

 

 

Basic Connection 

 

-Vin

+Vin

CNT

CASE

C1

C4

C3

C2

C5

+

-

Load

50mm

+

Fuse

+

+V

+S

-S

-V

POWER

MODULE

TRM

M3 threaded hole

M3 threaded hole

 

Fig.1-2 Basic Connection 

 
 

Input Fuse 

  This  power  module  has  no  built-in  fuse.  Use  external 
fuse  to  acquire  various  Safety  Standards  and  to  improve 
safety. Also, use fast-blow type for every module.   

  Furthermore, fuse must be connected to the +Vin side 
if  –Vin  side  is  used  as  ground,  or  fuse  must  be 
connected to –Vin side if +Vin side is used as a ground.   

 

Input Fuse recommended current rating:     
                    PAH300S24 : 30A     
                    PAH350S24 : 40A     

 

C1:   

  To  prevent  the  effect  of  input  line  inductance  to  the 
power  module,  connect  electrolytic  capacitor  or 
ceramic capacitor bVin and –Vin terminals.   
  Furthermore,  use  electrolytic  capacitor  with  small 
ESR  value.  Especially  take  note  that  during  line  turn 
off  at  low  ambient  temperature,  power  module  output 
will not normally shut down due to unstable C1 voltage.   
  Also,  ripple  current  flows  across  this  capacitor. 
Therefore,  verify  maximum  allowable  ripple  current 
this capacitor when selecting component. Verify actual 
ripple current value by actual measurement. 
 

Recommended capacitor value : 220

μ

×

2pcs and 

above (Parallel connect) 

(Voltage Rating 50V and above) 

   

Notes 

 

1.  Use  low  impedance  electrolytic  capacitor  with 

excellent temperature characteristics. 

   

    (Nippon Chemi-con LXY Series or equivalent) 

 
  2.  When  input  line  inductance  becomes  excessively   

high  due  to  insertion  of  choke  coil,  operation  of  the 
power module  could become unstable. For this case, 
increase C1 value more than the value indicated above. 

 
  3. When ambient temperature becomes lower than 
      –20

, connect 4 more and above capacitors indicated 

above in parallel to reduce ESR. 

 

C2, C3 : 0.022

μ

 

To  reduce  spike  noise  voltage  at  the  output,  connect 

film  capacitors  or  ceramic  capacitors  between  +V  and 
the nearest M3 threaded hole and between 

V and the 

nearest M3 threaded hole. 
  Also,  take  note  that  output  spike  noise  voltage  could 
vary  according  to  PCB  (printed  circuit  board)  wiring 
design. 
 
   
However, for cases where baseplate is connected to +V 
or –V, use the nearest M3 threaded hole. (M3 threaded 

t

Time

In

pu

t V

ol

ta

g

e

Vrpl

below 2V

Input Voltage

Range

 

Summary of Contents for PAH300 Series

Page 1: ...ionon electronic equipment For input terminalsof24 V inputmodels apply avoltagefromaprimary sourcewith reinforced ordouble insulation Output voltage of this product is considered to have hazardous ene...

Page 2: ...TP 9 Remote Sensing S S terminal 10 ON OFF Control CNT terminal 11 Parallel Operation 12 Series Operation 13 Operating Ambient Temperature 14 Operating Ambient Humidity 15 Storage Ambient Temperature...

Page 3: ...lter Baseplate CASE Switching Frequency fixed 330kHz typ Sequence Time Chart For Standard Model with Negative logic for ON OFF control Input Voltage Output Voltage 1 ON OFF Control L H 0V Vin 0V Vout...

Page 4: ...rminal CASE Baseplate Terminal S Remote Sensing Terminal CNT ON OFF Control Terminal TRM Output Voltage Trimming Terminal Vin Input Terminal S Remote Sensing Terminal V Output Terminal Baseplate can b...

Page 5: ...connect electrolytic capacitor or ceramic capacitor between Vin and Vin terminals Furthermore use electrolytic capacitor with small ESR value Especially take note that during line turn off at low amb...

Page 6: ...y that ripple current does not exceed allowable ripple current before use C5 0 1 F To reduce spike noise voltage at the output connect a ceramic capacitor between V and V within 50mm distance from the...

Page 7: ...ut and output wiring method as well as peripheral circuits When selecting input filter be sure to verify actual EMI characteristics CE and RE before finalizing the filter Refer to PAH300 350S24 Evalua...

Page 8: ...output voltage higher 2 1 Allowable maximum output current maximum output power output voltage reduce maximum output current in specification 2 2 Connect an external resistor Radj up between TRM term...

Page 9: ...note that power module might be damaged continuing output short circuit or over load conditions depending on thermal conditions 7 OverVoltageProtection OVP This power module has built in OVP function...

Page 10: ...l should be shorted to Vin terminal 2 When ON OFF control function is not used for the P option and PT option CNT terminal should be opened 3 When using long wiring for prevention of noise attach a 0...

Page 11: ...gh care when storing the power module because rust which causes poor solderability would form in each terminal when stored in high temperature high humidity environment 17 Cooling Method Operating tem...

Page 12: ...g a resistor etc DC Isolation Tester Vin CASE CNT Vin V S TRM S V Over 100M at 500VDC Fig 20 1 Isolation Test 21 Vibration Vibration of power module is defined in case of mounting on printed circuit b...

Page 13: ...m Land diameter 3 0 mm Output terminals 2 0 mm Hole diameter 2 5 mm Land diameter 4 5 mm Mounting Holes FG Hole diameter 3 5 mm Land diameter 5 5 mm For position of the holes see outline drawing of th...

Page 14: ...l 3 5 Non threaded hole 2 2 Standard model and Poption model M3 Threaded hole 3 Regarding Vibration The vibration specification of the module is determined assuming that only the power module is mount...

Page 15: ...ts For cases where output voltage adjustment is used is the resistor or volume setting connections correctly done 3 Output voltage is low Is specified input voltage applied Are the remote sensing term...

Reviews: