background image

・All specifications are subject to change without notice.

RTW 05-60R □

RTW

 

SERIES

■ Product Line up

Ultra-thin

Enclosed / Unit type

■ Applications

Y

E

A

R

S

warranty

5

■ Model-naming method

Symbol of shape/variation

50W, 100W, 150W
None: without cover
C: with cover
L: type L (terminal block facing upward, without cover)
300W
H: with cover (terminal block facing upward)
L: type L (terminal block facing upward, without cover)

Maximum output current (examples)

60R: 60A
4R3: 4.3A
2R1: 2.1A

Nominal output voltage

03: 3.3V 

15: 15V

05: 5V 

24: 24V

12: 12V 

48: 48V

Series name

UL62368-1

CSA62368-1

Low Voltage Directive

EN62368-1

Electrical  Appliance

and Material Safety Law 

DENAN

Built to meet

50W

100W

Output voltage Output current Without cover

With cover

Type L

Output current Without cover

With cover

Type L

3.3VDC

5VDC

12VDC
15VDC
24VDC
28VDC
48VDC

Conformity to RoHS Directive

■ Features

U

2

/

U

1

(

 

e

p

y

t

 

m

il

s

-

r

e

p

u

s

 ,

t

u

p

n

e

l

b

a

c

il

p

p

a

-

e

d

i

w

d

lr

o

W

 

rack size)

●  Meeting the standard of the harmonics current lim-

iter EN61000-3-2

●  

● 

1

1

/

8

/

6

/

5

/

4

/

3

/

2

-

4

-

0

0

0

1

6

N

E

 

h

ti

w

 

g

n

i

y

l

p

m

o

c

 

d

r

a

d

n

a

t

s

 

S

M

●  Complying  with  radiation  noise  and  conduction

noise regulations FCC-B and VCCI-B

●  Remote On/Off function incorporated (use and nonuse

can be switched by the internal switch)

●  Electrolytic capacitor lifetime: 60,000H or over

150W

300W

Output voltage Output current Without cover

With cover

Type L

Output current

With cover

Type L

Approved by safety standards, CE marking appli-

cable

12.5A

10A

4.3A
3.5A
2.2A
1.8A
1.1A

3.3VDC

5VDC

12VDC
15VDC
24VDC
28VDC
48VDC

35A
30A

12.5A

10A

6.3A
5.4A
3.2A

70A
60A
25A
20A
13A
11A

6.5A

RTW03-35RC
RTW05-30RC
RTW12-12RC
RTW15-10RC
RTW24-6R3C
RTW28-5R4C
RTW48-3R2C

RTW03-70RH
RTW05-60RH
RTW12-25RH
RTW15-20RH
RTW24-13RH
RTW28-11RH
RTW48-6R5H

RTW03-70RL
RTW05-60RL
RTW12-25RL
RTW15-20RL
RTW24-13RL
RTW28-11RL
RTW48-6R5L

RTW03-35RL
RTW05-30RL
RTW12-12RL
RTW15-10RL
RTW24-6R3L
RTW28-5R4L
RTW48-3R2L

RTW03-35R
RTW05-30R
RTW12-12R
RTW15-10R
RTW24-6R3
RTW28-5R4
RTW48-3R2

RTW03-12R
RTW03-12R
RTW12-4R3
RTW15-3R5
RTW24-2R2
RTW28-1R8
RTW48-1R1

RTW03-12RC
RTW03-12RC
RTW12-4R3C
RTW15-3R5C
RTW24-2R2C
RTW28-1R8C
RTW48-1R1C

RTW03-12RL
RTW03-12RL
RTW12-4R3L
RTW15-3R5L
RTW24-2R2L
RTW28-1R8L
RTW48-1R1L

25A
20A

8.4A
6.7A
4.2A
3.6A
2.1A

RTW03-25R
RTW03-25R
RTW12-8R4
RTW15-6R7
RTW24-4R2
RTW28-3R6
RTW48-2R1

RTW03-25RC
RTW03-25RC
RTW12-8R4C
RTW15-6R7C
RTW24-4R2C
RTW28-3R6C
RTW48-2R1C

RTW03-25RL
RTW03-25RL
RTW12-8R4L
RTW15-6R7L
RTW24-4R2L
RTW28-3R6L
RTW48-2R1L

1

ZHE

Summary of Contents for RTW Series

Page 1: ...on noise regulations FCC B and VCCI B Remote On O function incorporated use and nonuse can be switched by the internal switch Electrolytic capacitor lifetime 60 000H or over 150W 300W Output voltage O...

Page 2: ...mp p total amplitude 3 directions 1h for each in non operation 10 200Hz 10 minutes sweep 19 6m s 2G acceleration 3 directions 1h for each in non operation Shock Mounting A 196m s 20G Mounting B C 588m...

Page 3: ...Output voltage trimmer Indicator of output voltage On Outline Drawing 15max 124 98 5 0 5 6 2 M4 0 7 2 M3 0 5 Name plate Name plate Name plate 105 6 0 5 5 82 67 5 0 5 8 5 22 12 8 S S RC RC G L N Remote...

Page 4: ...case 4 Remote On Off terminal RC RC By inputting external signals between terminals the output voltage can be switched on and off from outside the power supply Output is not generated if voltage is no...

Page 5: ...2 33 7 21 25 8 82 10 5 7 03 9 04 4 41 5 25 3 78 4 86 2 2 2 62 Over Voltage Protection 7 VDC 4 2 5 2 6 0 6 9 13 7 15 7 17 0 19 0 27 0 30 5 32 0 35 0 55 0 60 0 Over Temperature Protection Not available...

Page 6: ...rame Cover Short plate Board Outline Drawing 15max 160 Output voltage trimmer 135 3 0 5 7 6 2 M4 0 7 2 M3 0 5 Name plate Name plate Name plate Name plate 121 7 0 5 20 5 82 69 7 0 5 6 3 24 2 12 1 S S R...

Page 7: ...utput is not generated if voltage is not applied to RC terminal The RC terminal is floated 5 Remote sensing terminal S S Used to compensate for a voltage drop to load The line between the remote sensi...

Page 8: ...0 35 0 55 0 60 0 e l b a l i a v a t o N n o i t c e t o r P e r u t a r e p m e T r e v O Remote Sensing Available Remote ON OFF Control 8 Available Parallel Operation Not available Series Operation...

Page 9: ...30 17 0 5 7 15 Type with cover RTW 150W The insertion length of screws used for mounting the power supply should be within 6mm from the product surface Unit mm Allowable tolerance is 1mm if not speci...

Page 10: ...is connected to the case 4 Remote On Off terminal RC RC By inputting external signals between terminals the output voltage can be switched on and off from outside the power supply Output is not genera...

Page 11: ...0 16 8 26 4 19 6 33 6 33 6 55 0 Function Over Current Protection 6 A 73 5 84 0 63 0 72 0 26 3 30 0 21 0 24 0 11 5 13 2 6 8 7 8 Over Voltage Protection 7 VDC Vo 0 66 1 32 Vo 1 0 2 0 Vo 2 4 4 8 Vo 3 0 6...

Page 12: ...ut voltage trimmer Indicator of output voltage On 20 0 5 Name plate Type with cover The insertion length of screws used for mounting the power supply should be within 6mm from the product surface Unit...

Page 13: ...5 10 5 10 5 10 5 4 5 4 5 9 5 05 250 237 05 9 5 2 5 2 5 120 115 05 61 5 05 2 5 11 11 10 4 5 4 0 33 27 2 39 2 20 05 97 05 105 5 05 37 179 05 60 5 UP 3 R2 25 Indicator of output voltage On Connector CN3...

Page 14: ...temperature C B C A Operatable range without guarantee 10 10 20 30 40 50 60 71 20 0 100 80 60 50 40 0 20 10 Output power Ambient temperature C Operatable range without guarantee B C A Type with cover...

Page 15: ...UV shut down 2 Remote O Remote On PF signal Open collector RTW300W RTW Block Diagram L N S S S RV CB RC RC AC input RC Control circuit PF PF Input lter circuit Input recti er circuit Surge current con...

Page 16: ...DC output terminal The insulation between the RC terminals and the out puts conforms to the specification of insulation resistance between output terminal and ground terminal and the withstand voltag...

Page 17: ...CB CB CB CB CB CN2 S Load Slave V ADJ RV CN3 S RV CN2 S V ADJ RV CN3 S RV CN2 Master 6 Current balance function CB terminal 300W When multiple power supplies are in parallel operation and their CB te...

Page 18: ...tom made power supply units variation models modified from this DC power supply device are not basi cally CE marking applicable except when CE marking applicable is specifically declared in their spec...

Page 19: ...i nal current value of the units in use In addition in order to prevent damage to internal elements and other parts due to reverse voltage applied to the unit connect a diode reverse withstand voltage...

Reviews: