This definition of a 0 dB FS signal must be understood when measuring the sensitivity of the T5919. A 1 kHz sine wave at a 94 dB SPL
acoustic input to the T5919 results in
an output signal with a −2
6 dB FS level (low-power mode). The output digital word peaks at
−
26 dB below the digital full-scale level. A common misunderstanding is that the output has an
RMS level of −2
9 dB FS; however, this is
not true because of the definition of the 0 dB FS sine wave.
Figure 11. 1 kHz, 0 dB FS Sine Wave
There is not a commonly accepted unit of measurement to express the instantaneous level, as opposed to the RMS level of the
signal, of a digital signal output from the microphone. Some measurement systems express the instantaneous level of an individual
sample in units of D, where 1.0 D is digital full scale. In this case, a −
26 dB FS sine wave has peaks at 0.05 D.