background image

A-3

            S

oftwAre

 L

icenSe

 A

greement

 / c

ompLiAnce

/e

miSSion

 S

tAtementS

DISCLAIMER OF WARRANTIES AND LIMITATION OF DAMAGES

TO THE EXTENT PERMITTED BY LAW, THIS ATM SOFTWARE, INCLUDING ALL INCORPORATED 

THIRD PARTY SOFTWARE, AND DERIVATIVES IS PROVIDED, “AS IS”.  TRITON MAKES NO REPRE-

SENTATIONS WITH RESPECT TO, AND DOES NOT WARRANT THE PERFORMANCE OR RESULTS YOU 

OR YOUR CUSTOMERS MAY OBTAIN BY USING THE ATM.  TRITON SPECIFICALLY DISCLAIMS ANY 

AND ALL WARRANTIES, EXPRESS, IMPLIED OR STATUTORY, INCLUDING WITHOUT LIMITATION, 

WARRANTIES OF QUALITY,  PERFORMANCE, NONINFRINGEMENT, AND MERCHANTABILITY OR 

FITNESS FOR ANY PARTICULAR PURPOSE.

TRITON MAKES NO REPRESENTATIONS OR WARRANTIES AND ASSUMES NO OBLIGATIONS TO 

YOU OR YOUR CUSTOMERS WITH RESPECT TO ANY TRANSACTION OR SERVICES ACCESSED 

AND/OR UTILIZED IN CONSUMER-INITIATED TRANSACTIONS MADE FROM THIS ATM.  IN NO 

EVENT WILL TRITON, ITS AFFILIATES, DIRECTORS, OFFICERS, EMPLOYEES, AGENTS OR SUP-

PLIERS BE LIABLE TO YOU UNDER ANY THEORY OF TORT, CONTRACT, STRICT LIABILITY OR 

OTHER LEGAL OR EQUITABLE THEORY FOR ANY PUNITIVE, CONSEQUENTIAL, INCIDENTAL, 

SPECIAL OR SIMILAR DAMAGES, INCLUDING ANY LOSS PROFITS OR LOST SAVINGS, EVEN IF A 

TRITON AGENT OR REPRESENTATIVE HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAM-

AGES, OR FOR ANY CLAIM BY ANY THIRD PARTY.

YOUR SOLE REMEDY AGAINST TRITON FOR DEFECTIVE PERFORMANCE OF THE ATM SOFTWARE 

WILL BE LIMITED EXCLUSIVELY TO REPAIR OR REPLACEMENT OF THE ATM AND/OR THE ATM 

SOFTWARE, AT TRITON’S SOLE DISCRETION.

Any warranty pertaining to the ATM, its mechanical components exclusive of the ATM software, shall be gov-

erned and controlled by any warranty given to you by Triton in a separate document accompanying this ATM.

The foregoing limitation of liability and exclusion of certain damages will apply regardless of the success or 

effectiveness of other remedies.

GOVERNING LAW:

  This License Agreement shall be governed by the laws of the State of Mississippi and 

by the laws of the United States, excluding their conflicts of laws principles.

SEVERABILITY:

  In the event any provision of this License Agreement is found to be invalid, illegal or un-

enforceable, the validity, legality and enforceability of any of the remaining provisions shall not in any way be 

affected or impaired.

ENTIRE AGREEMENT:

  This License Agreement and the accompanying Limited Warranty set forth the entire 

agreement between you and Triton, supersedes all prior agreements, whether written or oral, with respect to the 

ATM Software, and may be amended only in writing signed by both parties.

Summary of Contents for Triton VersaSafe

Page 1: ...on and Installation TDN 07103 00335 May 17 2012 Corporate Headquarters 21405 B Street Long Beach MS 39560 PHONE 800 259 6672 FAX 228 868 9445 2012 Triton All Rights Reserved TRITON logo is a registere...

Page 2: ...Describes anchoring the cabinet using standard steel or the optional chemical anchors Anchors provided separately Power and Communication Shows cable access area power requirements and powering up th...

Page 3: ...mizes the possibility of liquid or food spills 2 Site wiring power communication Ensure access will not be hindered by cabinet placement 3 Location of other equipment that may cause electrical electro...

Page 4: ...ted ground Dedicated source TheVersaSafe AC power feed will be a dedicated line to which no other electrical devices are connected The VersaSafe power line will be wired for a single duplex style outl...

Page 5: ...ess Unit shown with Bill Acceptor bracket extended En sure there is adequate room for the door to swing open DO NOT be tempted to place the cabi net on a table or other support Severe injury and equip...

Page 6: ...6 VersaSafeTM Installation Dimensions Deep Cabinet Physical Dimensions...

Page 7: ...nstalled 10 Remove the 4 four bolts and or nuts retaining the unit to the pallet UNLOCKING COMBINATION LOCKS Electronic Lock The combination of the lock is preset to 1 2 3 4 5 6 To unlock enter the pr...

Page 8: ...he previous step Drill the pilot holes approximately 1 2 12 mm deep into the floor These holes will help guide the masonry bit that will be used to drill the anchor bolt holes in the next step 3 Stand...

Page 9: ...to mounting holes Tap anchor mounts into mounting holes 4 Place a bolt into mount then place flat washer on the anchor bolt followed by a 1 2 13mm nut on top to secure Do not tighten fully allow for l...

Page 10: ...the cabinet not to be level 2 Begin by inserting a Chem Stud capsule into one of the mounting holes Either end of the capsule may be inserted first 3 Place a washer and a nut in that order onto a chis...

Page 11: ...dhesive to cure for the specified time see chart and important note which follows prior to applying any load to the anchors During the winter the hole temperature may be different than the room temper...

Page 12: ...ords are not recommended 2 AC power for the terminal should come from a dedicated source with an isolated ground The unit is designed to work on an IT Isolated Terra type power system having a phase t...

Page 13: ...board and serve as its power supply Use TY wraps to bundle cables if necessary The TDL Gateway modem will mount atop the units power supply A USB cable will provide power to the unit from the system s...

Page 14: ...height Ensure the four 4 mounting points between the VersaSafeTM and the Plinth are secure Do not be tempt ed to use less than the four 4 pieces of hardware supplied If more than one Plinth is used en...

Page 15: ...Appendix A Software License Agreement Compliance Emission Statements A 1...

Page 16: ...ense to use the ATM Software but only in connection with the operation of this ATM subject to the terms and restrictions set forth in this License Agreement You are not permitted to use the ATM Softwa...

Page 17: ...R REPRESENTATIVE HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAM AGES OR FOR ANY CLAIM BY ANY THIRD PARTY YOUR SOLE REMEDYAGAINSTTRITON FOR DEFECTIVE PERFORMANCE OFTHEATM SOFTWARE WILL BE LIMITED EXCL...

Page 18: ...otection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in a...

Page 19: ...Appendix B Warranty Service Statement B 1...

Page 20: ...AR PURCHASE LIMITATION OF LIABILITY IN NO EVENT SHALL MANUFACTURER BE LIABLE FOR LOSS OF PROFITS OR INCIDENTAL INDIRECT SPECIAL CONSEQUENTIAL OR OTHER SIMILAR DAMAGES ARISING OUT OF ANY BREACH OF THIS...

Page 21: ...ibutor s use of the goods or any of their parts by reason of infringement of a patent or other intellectual property right or if in Manufacturer s opinion the goods are likely to become the subject of...

Page 22: ...code on a unit or any component thereof or any attempt to repair a unit or to repair or replace any component by anyone other than a service technician authorized by Triton shall void this warranty W...

Page 23: ...ment is shipped Free On Board FOB Triton s facilities The organization or individual who has purchased the equipment assumes responsibility for the equipment once it leaves Triton s facilities Should...

Page 24: ...d Therefore we will not ship primary structural parts such as a cabinet head or main cabinet body for repair in the field Triton s Technical Services Department The primary purpose of the Technical Se...

Page 25: ...fication as a service technician or the serial number of a Triton terminal Technical support is provided during normal business hours for the life of the product When calling for help with an operatio...

Page 26: ...B 8 Appendix B This Page Intentionally Left Blank...

Reviews: