4
V
ersa
s
afe
TM
I
nsTallaTIon
When installing a VersaSafe™, some general environmental and power precautions must be consid-
ered. Evaluate the location where the unit will be installed. To help ensure proper operation of the
unit, ensure the environmental criteria listed in this checklist are met.
n
etWork
C
onneCtiVity
(W
ireless
o
Ptional
)
3. Ensure the following network requirements are
met:
Proximity to Interference Sources.
The network
connection must not be in close proximity to “noisy”
devices that could induce interference into the units
communications channel. See the next section for ad-
ditional information on “interference sources.” Wireless
communications also available. Antenna placement is
critical.
rf i
nterferenCe
4. Ensure there are no devices near the terminal
that may cause RF interference, such as:
TVs
Coolers
Security devices
Neon signs
Devices with compressors or motors.
* IMPORTANT *
AC power for the terminal should
come from a dedicated source with an
isolated ground.
Dedicated source.
The VersaSafe™ AC power feed will
be a dedicated line, to which no other electrical devices
are connected. The VersaSafe™ power line will be
wired for a single “duplex”-style outlet and connected
directly to the AC service panel. (No extension cords)
Isolated Ground.
An equipment grounding conduc-
tor that is insulated from the conduit or raceway and
all other grounding points throughout its entire length.
The only points of electrical connection will be at the
duplex outlet and service panel ends of the line.
t
emPerature
/ H
umidity
1. The VersaSafe™ will operate over a range of
temperatures and humidity. Generally, these
parameters must fall within the following ranges:
Temperature
• 10°C to 40°C
• 50°F to 104°F
Relative Humidity
• 20% to 80%
• (Non-Condensing)
aC P
oWer
r
equirements
2. Ensure the following AC power requirements
are met:
Current (Max)
• 2.2A @ 115 VRMS at 60 Hz
• 1.1A @ 230 VRMS at 50 Hz
Voltage
• 90 - 136VRMS @ 50/60 Hz
• 198 - 257VRMS @ 50/60 Hz
Power Consumption (Idle)
• 0.6A @ 115 VAC at 60 Hz
• 0.3A @ 230 VAC at 50 Hz
Power Consumption (Max Load)
• 250 Watts @ 120VAC
• 250 Watts @ 240VAC
Surge ~50A @ 230V
e
nVironmental
P
reCautions
VersaSafe™ is designed for indoor use only.