DIGIgarde PLUS can be connected to other devices (access control units, lock,
door sensor, alarm, host PC etc) through the colour-coded and labelled connection
cables. In addition to the connections described in Table 5, there is also a pre-
configured RJ-45 connector.
Table 5
Cable Assignments
Label
Wire Colour
Signal
Description
Power
Black
0V
Power GND
Red
+12V
Power Input
WG IN
Black
GND
GND
White
WD0-IN
Wiegand Input, Data 0
Green
WD1-IN
Wiegand Input, Data 1
WG OUT
Yellow
WD0-OUT
Wiegand Output, Data 0
White
WD1-OUT
Wiegand Output, Data 1
Black
GND
Wiegand GND
Blue
LED
LED
Lock
White
SENSOR
Door Sensor power
Black
GND
Door Sensor ground
Grey
BUTTON
Egress button
Blue
NO1
Normally Open
Red
COM1
Common
Yellow
NC1
Normally Closed
Alarm
Orange
ALARM NO2
Alarm (Normally Open)
Green
ALARM COM2 Alarm (Common)
RS485-2
Blue
RS-485A-2
RX+, RS-485-2 level
Yellow
RS-485B-2
RX-, RS-485-2 level
RS232
Black
RS-232 0V
RS-232 0V
Grey
RS-232 RX
Receive Data, RS-232C level
Purple
RS-232 TX
Transmit Data, RS-232C level
RS485-1
Blue
RS-485A-1
RX+, RS-485-1 level
Yellow
RS-485B-1
RX-, RS-485-1 level
Black
GND
RS-485 GND
RS485RES
Brown
RS-485RES
Link wires to provide
termination resistor
(see page 19).
Brown
RS-485RES
NOTE.
RS232 and RS485 connections are not available on current build.