Device Settings
DIGIgarde PLUS User Guide
Last Change
Copyright
©
2012 TDSi
13 May, 2016
Page 37
4.2
4.2
4.2
4.2
Power
Power
Power
Power m
m
m
management
anagement
anagement
anagement
Use this option to set the idle time (in minutes). If the DIGIgarde PLUS receives no
keypad or fingerprint input within the Idle Time, it will go into a low power standby
mode. In this mode, the screen is blank and the scanning window is unlit. If a user
presses any key or places their finger on the scanning window, the DIGIgarde
PLUS ‘wakes’ and resumes normal operation.
4.3
4.3
4.3
4.3
Communication
Communication
Communication
Communication o
o
o
options
ptions
ptions
ptions
The DIGIgarde PLUS fully supports RS232, RS485 and TCP/IP communications
(see page 18 for connection details). Use the third option on the Options menu to
set the Communication Options.
Table 11
Communication options
Communication
Option
Use
Default
BaudRate
Set the baud rate for communications: 9600,
19200 38400, 57600 115200
115200
Dev Num
Choose the unit number for this DIGIgarde
PLUS device: 1-255
1
Net Speed
10M-H, 100M-H, 10M-F, 100M-F, AUTO
AUTO
IP Address
Define the IP address for this unit
192.168.1.201
Netmask
Define the Net Mask for this unit
255.255.255.0
Gateway
Enter the Gateway IP address for your
network.
0.0.0.0
Ethernet
Enable or disable Ethernet communications
Y
RS232
Enable or disable RS232 communications
Y
RS485
Enable or disable RS485 communications
N
COMM Key
Security key required to establish
communication between unit and PC
software. PC software must be configured
with matching key.
0
Comm Opt
↓
►
BaudRate 115200
Dev Num
1
Net Speed AUTO
Options
↓
System Opt
Power Mng
►
Comm Opt
Power Mng
►
Idle Min
5
Options
↓
System Opt
►
Power Mng
Comm Opt