Device Settings
DIGIgarde PLUS User Guide
Copyright
©
2012 TDSi
Last Change
Page 38
13 May, 2016
4.4
4.4
4.4
4.4
Log
Log
Log
Log o
o
o
options
ptions
ptions
ptions
The fourth option on the Options menu is Log Options. The DIGIgarde PLUS logs
three types of data:
Supervisor Log
Attendance Log
Fingerprint Alarm Log
Use the Log Options settings to determine when the unit is to indicate that the logs
are reaching its internal memory capacity.
Table 12
Log options
Log Option
Use
Default
Alm SuperLog
Supervisors Log: number of remaining log
entries when unit issues memory capacity
warning
99
Alm AttLog
Attendance Log: number of remaining log
entries when unit issues memory capacity
warning
99
FRecordAlarm
Fingerprint Record Log: number of remaining
log entries when unit issues memory
capacity warning
99
ReCheck Min
Set the minimum period for relogging a user.
If a user is verified a second time within this
period, only a single log entry is recorded.
0
4.5
4.5
4.5
4.5
LED
LED
LED
LED m
m
m
mode
ode
ode
ode
The Reader LED default is set to bi-colour. The LED line is held at approximately
5V, and in normal mode will pulse to 0 Volts every 2 seconds (red LED). Upon
access granted this will activate to 12 Volts (Green)for the duration of the
Lock
time
(see page 48).
In ACU mode the LED is driven from the ACU.
4.6
4.6
4.6
4.6
Data
Data
Data
Data o
o
o
out
ut
ut
ut ttttype
ype
ype
ype
Wiegand or Magnetic
The reader can output the User ID with or without a site code depending upon
which setting you have chosen. For connection to TDSi Access Control Panels use
37-bit Wiegand (28-bit data, 8-bit even parity, 1 bit odd parity) or Magnetic
protocols.
Comm Opt
►
BaudRate 115200
Dev Num
1
Net Speed AUTO
Options
↑
Power Mng
Comm Opt
►
Log Opt