Page 47 / 101 ECOC: EGC0 ; LOC: AI
528050-1
412-18876 Rev. G
8
Comissioning
8.1
Connecting to Compressed Air Supply
DANGER!
Due to the risk of hand or finger injury, never try to reach into the machine.
CAUTION!
The crimp machine is only allowed to be used with mounted adapter and die set.
The crimp machine is only allowed to be used when it is in complete functional
condition.
When working with the Pneum. Parallel Crimp Machine AT-SC, do not wear loose
clothing, jewellery or long, loose hair that can get caught in the Pneum. Parallel
Crimp Machine AT-SC.
Work with caution.
In cases of a machine malfunction, production must be stopped and the
malfunction must be fixed before continuing work with the machine.
Only one person is allowed to work on or with the machine.
Only trained personal are allowed to work on or with the machine.
It is only allowed to work with the specified working pressure.
Connect the colour coated, fourfold air hose on the
back of the machine (Fig. 8.01) and to the double
foot pedal (Fig. 8.02).
Green hose
→ A1 Green
White hose
→ B1 White
Black hose
→ A Black
Blue hose
→ P Blue
Fig. 8.01
Fig. 8.02
1
Summary of Contents for AT-SC
Page 32: ...Page 32 101 ECOC EGC0 LOC AI 528050 1 412 18876 Rev G 17 3 Pneumatik Schema Abb 17 02...
Page 65: ...Page 65 101 ECOC EGC0 LOC AI 528050 1 412 18876 Rev G 17 3 Pneumatic Diagram Fig 17 02...
Page 98: ...Page 98 101 ECOC EGC0 LOC AI 528050 1 412 18876 Rev G 17 3 Sch ma Pneumatique Fig 17 02...