Instruction Sheet
TOOLING ASSISTANCE CENTER 1-800-722-1111
PRODUCT INFORMATION 1-800-522-6752
This controlled document is subject to change.
For latest revision and Regional Customer Service,
visit our website at www.te.com
408-32046
CEELOK FAS-T* Cable Harness
Manufacturing Guide
02 APR 12 Rev A
Figure 1
1. INTRODUCTION
(Figures 1 and 2)
The following instructions detail the steps for
terminating the CEELOK FAS-T Connector harness.
Refer to documents: Raychem RCPS-100-70
installation procedure for solder sleeve termination;
Application Specification 114-32025 for CEELOK
FAS-T High Speed Circular Connector System; and
Installation Procedure ELE-3COP-375 for braid
termination using a band strap adapter.
Dimensions in this instruction sheet are in
millimeters [with inches in brackets]. Figures and
illustrations are for reference only and are not
drawn to scale.
Figure 2
1. Cut the cable to the desired length. Use an
appropriate cable cutter. Mark and strip
approximately 31.75 ±1.57 mm [1.25 ±.062 in.] of
cable jacket over the braid section. Refer to Figures
3 and 4.
Raychem is a trademark.
Figure 3
Figure 4
2. Fold the braid back over the cable jacket and
remove foil wrap (if it exists) to expose the internal
conductors. Refer to Figure 5.
Heat Sink Boot
Jam Nut
Coupling Ring
Cat6A Cable
Full Mate Indicator
Receptacle
Connector
Plug Connector
NOTE
i
Cable O.D. Range:
5.59-10.16 mm [.220-.400 in.]
Maximum Conductor
Insulation Diameter
1.27 mm [.050 in.]
Cat6A Cable