408-32046

CEELOK FAS-T* Cable Harness 
Manufacturing Guide

02 APR 12  Rev A

Figure 1

1. INTRODUCTION 

(Figures 1 and 2)

The following instructions detail the steps for 
terminating the CEELOK FAS-T Connector harness. 
Refer to documents: Raychem RCPS-100-70 
installation procedure for solder sleeve termination; 
Application Specification 114-32025 for CEELOK
FAS-T High Speed Circular Connector System; and 
Installation Procedure ELE-3COP-375 for braid 
termination using a band strap adapter.

Dimensions in this instruction sheet are in 

millimeters [with inches in brackets]. Figures and 

illustrations are for reference only and are not 

drawn to scale.

Figure 2

1. Cut the cable to the desired length. Use an 
appropriate cable cutter. Mark and strip 
approximately 31.75 ±1.57 mm [1.25 ±.062 in.] of 
cable jacket over the braid section. Refer to Figures 
3 and 4.

Raychem is a trademark.

Figure 3

Figure 4

2. Fold the braid back over the cable jacket and 
remove foil wrap (if it exists) to expose the internal 
conductors. Refer to Figure 5.

Heat Sink Boot

Jam Nut

Coupling Ring

Cat6A Cable

Full Mate Indicator

Receptacle 

Connector

Plug Connector

NOTE

i

Cable O.D. Range:

5.59-10.16 mm [.220-.400 in.]

Maximum Conductor 

Insulation Diameter 

1.27 mm [.050 in.]

Cat6A Cable