409-35011
Rev C
24
of 54
Figure 26
3. The production screen is where Articles are both created and run. This is the screen that will be most-
used with operation of the HV-CP (see Figure 26).
4. Settings
a. To expand tool bar in the UI, select the menu collapse arrow to expand the options.
b. To hide this menu, select the menu collapse arrow again.
Initial Startup
Power Up
The main power disconnect is mounted on the left side of the machine (see Figure 20). Turning the switch
to the “OFF” position disconnects the incoming power. It can be locked out for safety and security
proposes. Turn it to the “ON” position to start the machine. The machine will power
-up accordingly. With
electricity to the machine, the pneumatic pressure switch will read the pressure entering the machine. The
machine will not run if the pressure value on the pneumatic pressure switch is too high or too low. Refer to
section 3.3. for the correct pressure.
Auto Start Button
Manual Cycle Start Button
Production Screen
Menu Expand/Collapse