Connecting Contact Alarms to a Fusion Wideband System
7-62
InterReach Fusion Wideband Installation, Operation, and Reference Manual
CONFIDENTIAL
D-620616-0-20 Rev F
7.7.3
Alarm Cables
5-port Alarm Daisy-Chain Cable
Figure 7-38 shows the 5-port Alarm Daisy-Chain Cable (PN 4024-3), which supports
fault and warning conditions.
Figure 7-38
5-port Alarm Daisy-Chain Cable
DB-9 female to
Base Station,
FlexWave Focus,
or
J1
Female
J2
Male
J3
Male
J4
Male
J5
Male
J6
Male
J7
Female
Terminator
Splice
Splice
Splice
Splice
Splice
Splice
Splice
Splice
7
9
4
5
7
9
4
5
7
9
4
5
7
9
4
5
7
9
4
5
7
4
1.2 meters (4 feet)
.5 meter
(1.5 feet)
DB-9 male to Fusion,
Unison, FlexWave
Focus, Alarm Port
DB-9 male to Fusion,
Unison, FlexWave
Focus Alarm Port
DB-9 male to Fusion,
Unison, FlexWave
Focus Alarm Port
DB-9 male to Fusion,
Unison, FlexWave
Focus Alarm Port
Option 1: DB-9 to Fusion,
Unison, FlexWave
Focus
Alarm Port.
J7 not used
Option 2: Use J2-J5
for alarm ports. J6 is used
to connect to an additional
Alarm Daisy-Chain Cable.
J7 is not used.
Option 3: Connect
fewer than 5 ports and
terminate the daisy chain
by connecting J7 to the
lowest unused port.
Connector
Hood
.5 meter
(1.5 feet)
.5 meter
(1.5 feet)
.5 meter
(1.5 feet)
.25 meter
(.75 feet)
the Alarm Sense
Adapter Cable when
connecting Unison
NOTE:
Do not daisy-chain Fusion
Wideband Main Hubs with FlexWave
Focus if you want both faults and
warnings from Fusion. Only faults are
reported if you combine Fusion with
FlexWave in the same daisy chain.