background image

NOTE

i

Application Specification

© 2012 Tyco Electronics Corporation, a TE Connectivity Ltd. company

 

All Rights Reserved
*Trademark  

TE Connectivity, TE connectivity (logo), and TE (logo) are trademarks.  Other logos, product and/or company names may be trademarks of their respective owners. 

1

 of 8

TOOLING ASSISTANCE CENTER 1-800-722-1111

 

PRODUCT INFORMATION 1-800-522-6752

This controlled document is subject to change.

 

For latest revision and Regional Customer Service, 
visit our website at 

www.te.com

114-1016

 

Miniature AMP-IN* Contacts and 
Miniature AMP-IN 2000 Contacts

16 OCT 12  Rev EE

All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. 

Unless otherwise specified, dimensions have a tolerance of ±0.13 [±.005] and angles have a tolerance of ±2°. Figures 

and illustrations are for identification only and are not drawn to scale.

 

1. INTRODUCTION

This specification covers the requirements for application of miniature AMP-IN contacts and miniature AMP-IN 
2000 contacts. These contacts are designed to hold the strands of wire together so that the wire can be inserted 
into holes in a printed circuit (pc) board.

Each contact features a wire barrel, insulation barrel, locking lance(s), and stabilizer barrel or insulation stop/
positive board stop. The locking lance is designed to prevents the contact from backing out of the pc board hole. 
The stabilizer barrel holds the contact steady during the soldering process, and the insulation stop/positive 
board stop prevents the wire insulation from being inserted and the contact from being over inserted into the pc 
board hole. These requirements are applicable to automatic termination machines. 

When corresponding with personnel, use the terminology provided in this specification to facilitate your inquiries 
for information. Basic terms and features of this product are provided in Figure 1.

 

Miniature AMP-IN Contact

Miniature AMP-IN 2000 Contact

Insulation Stop/

Positive Board Stop

Locking Lance

Wire Barrel

Insulation 

Barrel

Wire Barrel

Insulation 

Barrel

Stabilizer 

Barrel

Locking Lance 

(2 Places)

Figure 1

2. REFERENCE MATERIAL

2.1. Revision Summary

Revisions to this application specification include:

Corrected inch conversion for pc board thickness in Paragraph 3.4

2.2. Customer Assistance

Reference Product Base Part Numbers 640401 and 794121 and Product Code 1326 are representative of 
miniature AMP-IN contacts and miniature AMP-IN 2000 contacts. Use of these numbers will identify the product 
line and help you to obtain product and tooling information. Such information can be obtained through a local 
Representative, by visiting our website at www.te.com, or by calling PRODUCT INFORMATION or the 
TOOLING ASSISTANCE CENTER at the numbers at the bottom of this page.

2.3. Drawings

Customer Drawings for specific products are available from the responsible Engineering Department via the 
service network. The information contained in the Customer Drawings takes priority if there is a conflict with this 
specification or with any other technical documentation supplied.

Summary of Contents for Miniature AMP-IN

Page 1: ...uring the soldering process and the insulation stop positive board stop prevents the wire insulation from being inserted and the contact from being over inserted into the pc board hole These requireme...

Page 2: ...lection and Preparation The contacts accept stranded wire sizes 26 to 10 AWG with an insulation diameter range given in Figure 2 Wire strip length shall be as given in Figure 2 CAUTION Care shall be t...

Page 3: ...ar Bellmouth 0 38 015 Max End of Wire Conductor to Wire Barrel X X Miniature AMP IN 2000 Contact X X See Detail A See Detail A Wire Insulation Not Crimped in Stabilizer Barrel Wire Conductors and Insu...

Page 4: ...034 114 1016 4 of 8 Rev EE Figure 3 End F Cutoff Tab and Burr The carrier strip cutoff tab and burr must be no more than the dimensions given in Figure 3 G Rear Bellmouth The rear bellmouth length mus...

Page 5: ...7 003 794013 12 3 18 0 08 125 003 794037 12 3 18 0 08 125 003 10 3 76 0 08 148 003 Miniature AMP IN 2000 794121 22 20 1 83 0 08 072 003 18 1 96 0 08 077 003 794122 26 22 1 40 0 10 055 004 Figure 4 3 5...

Page 6: ...opyl Alcohol Solvent 5 100 C 212 F KESTER 5778 Aqueous KESTER 5779 Aqueous LONCOTERGE 520 Aqueous LONCOTERGE 530 Aqueous Terpene Solvent C Cleaning After soldering removal of fluxes residues and activ...

Page 7: ...onitor CQM Applicators for Side Feed and End Feed Applications See Table 408 9640 AMP O LECTRIC Model G Terminating Machines 354500 409 5842 Miniature AMP IN 26 22 1 02 1 78 040 070 466739 1 466739 4...

Page 8: ...THROUGH PC BOARD HOLE LOCKING LANCE MUST BE COMPLETELY THROUGH PC BOARD HOLE WIRE INSULATION SHOULD NOT BE CRIMPED IN STABILIZER BARREL INSULATION STOP POSITIVE BOARD STOP MUST NOT BE TERMINATED THERE...

Reviews: