Strip Length (See Table)
Miniature
AMP-IN
350566
22-18
1.52-2.79 [.060-.110]
4.51 [.178]
640108
26-22
1.52-2.54 [.060-.100]
640311
22-18
1.52-2.79 [.060-.110]
4.83 [.190]
640401
26-22
1.02-2.54 [.040-.100]
640663
26-22
1.02-1.78 [.040-.070]
4.51 [.178]
770060
18-14
2.29-3.81 [.090-.150]
5.21 [.205]
770565
22-18
1.52-2.79 [.060-.110]
4.33 [.170]
794013
12
2.29-3.81 [.090-.150]
5.21 [.205]
794037
12-10
5.08 [.200] Max
Miniature
AMP-IN 2000
794121
22-18
1.27-2.79 [.050-.110]
5.08 [.200]
794122
26-22
1.27-2.79 [.050-.110]
114-1016
3
of 8
Rev
EE
Figure 2
Miniature AMP-IN Contact
0.64 [.025] Min
Locking Lance Height
Wire Conductors and Insulation
Both Visible Between Wire
Barrel and Insulation Barrel
0.25 [.010]
Rear Bellmouth
0.38 [.015] Max
End of Wire
Conductor to
Wire Barrel
X
X
Miniature AMP-IN 2000 Contact
X
X
See Detail A
See Detail A
Wire Insulation Not Crimped in Stabilizer Barrel
Wire Conductors and Insulation Visible
Between Insulation Barrel and
Insulation Stop/Positive Board Stop
Y
Y
Y
Y
3.56 [.140] Min
Between
Locking Lances
0.08 [.003]
Wire Barrel Flash
Wire Barrel Seam
Closed (or Can Be
Slighty Open) with
No Strands Visible
Section X-X
Detail A
0.08 [.003]
Max Burr
0.38
[.015] Max
Cutoff Tab
Wire Barrel or Stabilizer Barrel
Crimp Height
Wire Barrel or
Stabilizer Barrel Crimp
Width
Section Y-Y
Insulation Barrel Crimp
Width
Stabilizer Barrel Can Have
F-Crimp or “O” Crimp
Wire
Barrel
Insulation
Barrel
Stabilizer
Barrel
Wire
Barrel
Insulation
Barrel
Figure 3 (Cont’d)
CONTACT
WIRE
TYPE
BASE PART NUMBER
SIZE (AWG)
INSULATION DIAMETER
STRIP LENGTH
(±0.38 [±0.15])