Raychem Devices
No: RCPS-200-20
Rev: E1
Date: August 10, 2016
Installation Procedures for D-436-XX and D-200-XX
(Miniseal™) Sealed Crimp Splices
_________________________________________
Unless otherwise specified dimensions are in millimeters. [Inches dimensions are in between brackets]
© 2007-2016 TE Connectivity Corporation. All rights reserved.
If this document is printed it becomes uncontrolled. Check for the latest revision.
5.4.2.
Splicing Procedure
(1) Insert one of the multiple wires through each hole of the multiple-hole seal, and slide
the sealing sleeve back over the multiple wires as shown.
(2) Crimp the wires in the crimp splice as shown in the appropriate figure below.
* Make sure that the multiple wires do not become crossed between the multiple-hole
seal and the crimp splice.
(3) Center the sealing sleeve over the splice area as shown.