Raychem Devices
No: RCPS-200-20
Rev: E1
Date: August 10, 2016
Installation Procedures for D-436-XX and D-200-XX
(Miniseal™) Sealed Crimp Splices
_________________________________________
Unless otherwise specified dimensions are in millimeters. [Inches dimensions are in between brackets]
© 2007-2016 TE Connectivity Corporation. All rights reserved.
If this document is printed it becomes uncontrolled. Check for the latest revision.
(2) Insert the multiple wires coming from the other direction through the separate seal,
one wire per hole, as shown.
(3) Crimp the wires in the crimp splice as shown below.
Make sure that the multiple wires do not become crossed between either one of
the multiple-hole seals and the crimp splice.
(4) Push the separate multiple-hole seal up against the crimp splice.
(5) Position the sealing sleeve over the splice and over the separate multiple-hole seal so
that the separate seal is fully seated within the end of the sealing sleeve as shown.
Squeeze the wires together to hold the separate seal against the splice while
moving the sealing sleeve into position.