EPP-1988-INT-7/13 2/20
Before Starting
Check to ensure that the kit you are going to use fi ts the cable.
Refer to the kit label and the title of the installation instruction.
Components or working steps may have been improved since you last installed this product.
Carefully read and follow the steps in the installation instruction.
General Instructions
Use a propane (preferred) or butane gas torch.
Ensure the torch is always used in a well-ventilated environment.
Adjust the torch to obtain a soft blue fl ame with a yellow tip.
Pencil-like blue fl ames should be avoided.
Keep the torch aimed in the shrink direction to preheat the material.
Keep the fl ame moving continuously to avoid scorching the material.
Clean and degrease all parts that will come into contact with adhesive.
If a solvent is used follow the manufacturer’s handling instructions.
Tubing should be cut smoothly with a sharp knife leaving no jagged edges.
Start shrinking the tubing at the position recommended in the instruction.
Ensure that the tubing is shrunk smoothly all around before continuing along the cable.
Tubing should be smooth and wrinkle free with inner components clearly defi ned.
The Information contained in these installation instructions is for use only by installers trained to make electrical power
installations and is intended to describe the correct method of installation for this product. However, TE Connectivity has no
control over the fi eld conditions which infl uence product installation.
It is the user’s responsibility to determine the suitability of the installation method in the user’s fi eld conditions. TE Connectivity’s
only obligations are those in TE Connectivity’s standard Conditions of Sale for this product and in no case will TE Connectivity
be liable for any other incidental, indirect or consequential damages arising from the use or misuse of the products.
Raychem, TE Connectivity and TE connectivity (logo) are trademarks.
© 2011 Tyco Electronics Raychem GmbH.