TE-3X48WW PARLED AQUA
ADD : 19 Lacist St. Wesbrark, Maine, U.S.A. (04092)
sales@te-lighting.com
Phonel : (1) 207-712-3004
http://www.te-lighting.com
2.3
SETT ING UP W ITH A D MX512
CONT ROLLER
2.3-1 DM X512 ADDRESSING WITHOUT ID ADDR ESSING
MODE)
(Std.2
The figur e above shows a simple D MX512
layout w ith the s tarting address of the first
uni t set at 1, w ith the se cond set at 7 and
so on... ( Note that whe n used in this w ay,
the CH6 ID function mu st be inactiv e ( C H6=0))
DM X 512
CON TRO LLE R
●
●
●
●
●
●
C onne ct the DMX512 controller to the units i n series .
Each u nit has 6 D MX channels so the D MX Addresses should inc rease by increments of
6 ( e.g. 1,7,13,19...)
T he ID addr es s has no t been set so th er efore when u sing the contro ller Ch6 must
be inactiv e ( C H6=0 ) .
Each D MX Address may be used as many times as r equired.
Any DMX address in t he range fr om 001 to 512 may be used.
It is als o possi ble to deactivate ID address selecting
fr om the
menu.
on the fixture
【
】
【
】
ID OFF
Settings
2.3-2 DM X512 ADDRESSING WITH ID ADDRESS
MODE )
(Std.2
Connect the DMX5 12 controller to the units i n se ries
Eac h unit has 11 D MX channels so the D MX Addr esses should increase by incre ments of
6 ( e.g. 1,7,13,19...)
Eac h D MX Addres s may be used a s many times a s required.
Any DMX address in the range fr om 001 to 512 may be used.
Eac h D MX addr ess may carry up to 66 separate ID addresses.
should be s et in the menu on each unit in a scending value s
(i .e . 1,2,3...)
ID a ddresses ar e a ccessible fr om CH6 on the D M X512 controller.
●
●
●
●
●
●
●
●
【
】
【
】
【
】
ID
ID On
Se tting s
should b e set in the
menu on eac h unit.
Exampl e :
........ ....
DM X Add r.1
DMX Add r.7
DM X Add r.1 3
D MX5 12
C ON T ROL L ER
Example:
The figur e abov e shows a simp le D MX layout
w hich has used three units at each D MX addre ss.
The three units have different ID addresses w hic h
allows the user to collectively c ontrol the whol e
group of units a t that D MX addr ess by setting
C H6 to 0, or to c ontr ol eac h uni t independently by
first selecting th e D MX address and then by us ing
C H6 to locate th e target ID addr ess .
............
DMX Add r.1
ID A dd r.1
DM X A ddr.1
ID Add r.2
DM X Ad d r.1
ID Addr .3
DM X Add r.7
ID Add r.1
DM X Ad d r.7
ID Add r .2
D MX A dd r. 7
ID Add r.3
5