bracket welded on the silencer, fix it at a position
where it is not likely to hinder electric cables or
fuel pipes.
Do not use silencers not
supplied by TELAIR Silencers that have not
been specially sized may damage the motor.
4.13 Connecting an External Network Relay
An (optional) relay or change-over switch code
05423 (Fig.28) should be fitted to the vehicle
wiring system. Its purpose is to insulate the
generating set when the vehicle is connected to
an external electric input network.
Connect the relay (Fig.29) according to the
following instructions:
•
Connect the two wires of the 230 V line of the
generating set to the PINS 1 - 3.
•
Connect the user line to the PINS 7 - 9.
•
Connect the outside line to the PINS 6 – 4.
•
Jumper the PINS 4 – A.
•
Jumper the PINS 6 – B.
•
Connect all the grounding cables together
Electric connections to
the generating set should be carried out by
skilled electricians only.
5 OPERATING INSTRUCTIONS
The generating set is
delivered without engine oil.
Use detergent oil for multigrade 4-stroke
petrol engines, having SAE viscosity suitable
for the operating climate (see table and
detailed indications on the user and
maintenance manual of the engine).
ENERGY series generators consist of petrol
internal combustion engines connected to an
alternator that can produce both alternating and
direct electrical current. The generating sets are
assembled inside a steel plate casing, insulated
and sound-proofed using special sound
absorbing materials.