9
START_TRIGGER
Recording start conditions
COMMAND: Command
DATE: Start time setting
EXT: External trigger
TIME_OUT: Timeout
SYNC: Synchronized recording
PRE: Added for a pre-trigger
STOP_CONDITION
Recording stop conditions
COMMAND: Command
LEVEL: Level trigger
TIMER: Specified recording time
EXT: External trigger
MEDIA FULL: When media becomes full
SYNC: Synchronized recording
POST: Added for a post-trigger
START_PRE_COUNT
Number of scans recorded by a pre-trigger
STOP_POST_COUNT
Number of scans recorded by a post-trigger
MARK
Number of scans at the instant an event mark was attached.
VOICE_MEMO
The bits per sample and data size (bytes) for voice memos
LX-1000_VERSION
LX-1000 main firmware and FPGA versions and amplifier unit firmware and FPGA
versions
DIVIDE
File division number (added when files are divided at 4GB intervals)
SYNC
Synchronized recording setting