1-6.  Recording media

Open the SD card slot cover of the LX-1000 unit to 
access the SD card slot.

1-6-1.  Media types

Compatible media

SDHC/SDXC cards

Recording capacity

8 GB – 128 GB

Recommended speed class

Class 10

1-6-2.  Media that has been verified to 

operate with this system

This system uses SDHC and SDXC cards for recording and 
playback.
We provide a list of SDHC and SDXC cards that we 
have verified for operation with this system on our 
Information Products Division data recorders website.

https://datarecorder.jp/en/

You can also contact us. (For contact information, see the 
last page.)

 

o

In this manual, SDHC/SDXC cards are referred to as 
“SD cards”.

 

o

Prepare media for use only with the LX-1000.

 

o

To ensure stable recording, try to keep the total quan-
tity of recorded data to 1000 or less. Moreover, before 
recording, confirm that the recording medium has 
enough open space.

 

o

Do not use a computer to delete, move or otherwise 
alter data recorded on an SD card. Doing so could 
cause the LX-1000 to become unable to properly 
record or play data.

1.  Introduction

1-7.  TAFFmat format

1-7-1.  Type of files

The LX-1000 makes a binary-format data file and ASCII-
format header file each time recording stops or pauses.

Data file:

Contains data converted from 
analog to digital, etc.
(binary format with “dat” file 
extension)

Header file:

Contains recording conditions 
and other information
Text (ASCII) format with “hdr” 
file extension

Voice memo file*:

Contains voice memo data
WAV format with “wav” file 
extension

GPS file*:

Contains GPS data
“gps” file extension

Index file:

Contains recording conditions 
and other information
Text (ASCII) format with “hdx” 
file extension

*Files are created when recorded.

1-7-2.  File name

The file name is common to the data file and header file. 
An ID number is added to the end of the specified file 
name. When you specify a new file name, the ID num-
ber starts from 1. After recording is stopped or paused, 
the ID number is automatically incremented each time 
the recording restarts. If a data file with the same name 
or same ID number already exists when recording, the 
next ID number is used.
Set the file name on the LXK Navi File Settings Screen 
or the RECORDING FILE Settings Screen of the remote 
control unit (optional). For the file name, use up to 
29  half-width alphanumeric characters. ID numbers 
(starting from 001) with the set number of digits are 
attached to file names.
When recording to an SD card, the number of digits is 
fixed to 3, and the maximum number of characters is 32.
When recording to a computer, the number of digits 
can be set from 3 to 5, and the maximum number of 
characters is 32–34.

 

o

If the ID number exceeds the set number of digits, 
recording will stop.

Summary of Contents for LX-1000 Series

Page 1: ...Instructions for Use Z LX 1000 D01361310C...

Page 2: ...tion 20 Input format 20 Connected type 20 5 3 External trigger signal input TRIG IN 21 Function 21 Input circuit format 21 Input format 21 Connected type 21 Connection examples 21 5 4 DIGITAL CONTROL...

Page 3: ...ords included with this product are designed for use with these units Do not use them with other equipment 1 3 Overview Recording with wide bandwidths multi channels and long durations is becoming inc...

Page 4: ...tions o o DC input and IEPE sensor input can be used for ana log input o o Signal line interruption detection for each channel when using IEPE sensors o o Reads IEPE sensor TEDS information o o Analog...

Page 5: ...erted from analog to digital etc binary format with dat file extension Header file Contains recording conditions and other information Text ASCII format with hdr file extension Voice memo file Contain...

Page 6: ...ded automatically Recording data Same as recording folder When a recording is divided at 4 GB a followed by a three digit suffix will be added to the name Folder structure example root s Root folder L...

Page 7: ...the value would be 25000 when the input is 100 in the input range settings 24 bit converted data is recorded as integer values from 8388608 to 8388607 and the value would be 6400000 when the input is...

Page 8: ...axis units Sec This is a fixed value COMMENT Comment input on the file settings screen NUM_SERIES Number of recording channels STORAGE_MODE Data order Fixed as INTERLACED because this is the scan ord...

Page 9: ...full SYNC Synchronized recording POST Added for a post trigger START_PRE_COUNT Number of scans recorded by a pre trigger STOP_POST_COUNT Number of scans recorded by a post trigger MARK Number of scans...

Page 10: ...ndustry Canada s Compliance Statement This Class A digital apparatus complies with Canadian ICES 003 Cet appareil num rique de la classe A est conforme la norme NMB 003 du Canada Model for Europe DECL...

Page 11: ...and waste batteries accumulators correctly you will help save valuable resources and prevent any potential negative effects on human health and the environment c Improper disposal of waste electrical...

Page 12: ...r disconnecting connection cables turn off the power to the AC adapters o o Place AC adapter bricks away from the main unit LX 1000 and expansion units AU LX1000EPIO o o When using in Japan use the in...

Page 13: ...ng all connection cables between units o o Before disconnecting connection cables turn off the power to the DC INs 3 3 Installing amplifier modules Amplifier module Blank panel o o Amplifier modules c...

Page 14: ...the time required for measurement preparations o o If transducer information is not compliant with the TEDS IEEE standard correct information cannot be loaded and displayed o o Supports TEDS Ver 1 0...

Page 15: ...main unit Oscilloscope etc Input setting IEPE Input setting AC Input setting DC Piezoelectric accelerometer Example Voltage output type with built in preamp 730ZT triaxial type that supports TEDS SA 6...

Page 16: ...can be used to output a monitor signal which can be the input signal of any channel K Input output amplifier module slots Install input output amplifier modules here A STANDBY ON button Press and hold...

Page 17: ...ulse being input when pulse record ing is on Lit red3 Pulse data is exceeding the range maximum GPS Lit green When GPS is on data recording is on and satellite is captured Blinking green When GPS is o...

Page 18: ...output connector for external control Use to control recording and playback with contact signals and to connect a remote control unit option F Expansion unit DC power input DC IN 2 3 EPIO connector W...

Page 19: ...IO con nect all the FG frame grounding connectors of the main LX 1000 and expansion units to something suitable for grounding K Joints Mechanically connect the main unit LX 1000 to an expansion unit A...

Page 20: ...d 11 Reserved 12 Reserved 13 Reserved 14 Ground 15 PPS input for GPS 16 Reserved 17 Reserved 18 Reserved 19 Reserved 20 Ground ATTENTION o o Do not connect anything to the Reserved pins o o Pins 1 and...

Page 21: ...external trigger signal input reaches the L level Use contact and non contact tran sistor or TTL open collector to achieve L level 1 Contact signal connection example Transistor connection example TTL...

Page 22: ...served pins o o Pins 1 2 19 and 20 are for an optional remote control unit Do not use them for any other purpose 5 5 DC IN power input The DC IN power input connector can supply power to the main unit...

Page 23: ...ving the switch to the LOCK position o o Slide the write protection switch to one direction completely o o To use an SD card for recording or to erase recording data on it or format it unlock the writ...

Page 24: ...20 00 51 20 20 00 32 768 12 80 200 80 24 00 10 00 20 00 8 00 25 60 10 00 16 384 6 40 100 40 12 00 5 00 10 00 4 00 12 80 5 00 8 192 3 20 50 20 6 00 2 50 5 00 2 00 5 12 2 00 4 096 1 60 10 4 3 00 1 25 2...

Page 25: ...26 10 5 44 51 3 00 1 25 158 28 12 85 19 48 44 22 18 22 38 19 11 26 10 1 50 0 63 277 19 22 158 28 12 85 19 48 44 22 18 22 38 19 o o The recording times given in the above tables are approximations Act...

Page 26: ...r an optional remote control unit Voice memo or monitoring signal selection function The signal source for voice memo output can be set to either the voice memo or the monitoring output 7 Specificatio...

Page 27: ...Rated output voltage 16 V Rated output current 6 5 A External dimensions W H D 68 35 153 mm Weight 650 g or less Operating conditions Operating temperature humidity range 0 to 40 C 10 to 80 no conden...

Page 28: ...500 Hz 1 kHz 2 kHz 5 kHz 10 kHz 20 kHz Measurement precision 0 2 using 24 bit AD 0 3 using 16 bit AD 5 rpm mode Measurement ranges 1500 rpm 3000 rpm 6000 rpm 9000 rpm 12000 rpm 15000 rpm 18000 rpm 24...

Page 29: ...supply DC 24 V 4 mA IEPE sensor disconnection detection Detection function included for each channel Yellow LED blinks when disconnected TEDS Supports TEDS Ver 1 0 AR LXST1000 strain input amplifier...

Page 30: ...nded range 127 of rated range Digital analog conversion method conversion method Output frequency flatness characteristics 20kHz bandwidth 0 15 dB 40kHz bandwidth 0 30 dB Phase difference between outp...

Page 31: ...ed in all the input output amplifier module slots The configuration of input and output amplifier modules depend on the content at the time of order o o When any number of AR LXST1000 modules are inst...

Page 32: ...32 48 channel model 300 200 65 14 44 44 64 channel model 300 200 65 14 44 44 44 Unit mm 8 Exterior drawings...

Page 33: ...mask and other item set correctly Is it blocked by a computer firewall Try turning the LX 1000 off and on again and then restart LXK Navi If you are still unable to fix the problems after checking th...

Page 34: ...damage if the product was not pur chased from our company or an agent designated by our company o o We offer paid service after the conclusion of the war ranty period For details please contact the r...

Page 35: ...35...

Page 36: ...anta Fe Springs California 90670 U S A Phone 1 323 726 0303 TEAC EUROPE GmbH Bahnstrasse 12 65205 Wiesbaden Erbenheim Germany Phone 49 0 611 7158 349 EU Importer TEAC SALES TRADING Room 817 Xinian Cen...

Reviews: