68
Setting example 1
D/A Zero
000.00
D/A Full Scale
100.00
Reading
D/A Output
100.00
10V(20mA)
000.00
0V(4mA)
–100.00
–10V(--mA)
Setting example 2
D/A Zero
020.00
D/A Full Scale
100.00
Reading
D/A Output
120.00
10V(20mA)
020.00
0V(4mA)
–80.00
–10V(--mA)
Setting example 3
D/A Zero
020.00
D/A Full Scale
-100.00
Reading
D/A Output
120.00
–10V(20mA)
020.00
0V(4mA)
–80.00
10V(--mA)
Setting example 4
D/A Zero
-10.00
D/A Full Scale
20.00
Reading
D/A Output
100.00
10V(20mA)
000.00
5V(4mA)
–10.00
0V(--mA)
12-5. D/A output error
Below are the messages that are displayed when errors are
caused by the D/A option.
dErr: the D/A output is higher than +10.9 V.
-dErr: the D/A output is lower than -10.9 V.
12. D/A Converter (TD-260T AC(D/A) / TD-260T DC(D/A) )