42
9-8-3. SYSTEM - CAN
Parameter
Default value
Setting values
Note
Use
OFF
OFF/ON
Por
t settings
Baud rate
500kbps
125kbps/200kbps/250kbps/
500kbps/1000kbps
Sampling point
73.3%
60.0%/66.7%/73.3%/80.0%/86.7%
BSP
Triple
Single/Triple
SJW
4
1/2/3/4
Mode
Normal
Normal/Listen only
Sig
nal settings
ID type
Standard
Standard/Extended
Frame ID
0
Start bit
0
0–63
Bit length
1
1–64
Byte order
Intel
Intel/Motorola
Value type
Unsigned
Unsigned/Signed/Float/Double
Name
Signal XX
20 ASCII characters
maximum
Unit
20 ASCII characters
maximum
Coefficient
1.0000000
Offset
0.0000000
IGNI trigger
OFF
OFF/ON
9-8-4. SYSTEM - GPS
Parameter
Default value
Setting values
Note
Data recording
OFF
OFF/ON
Time zone
Time zone
Japan
Japan/UTC/Custom
Difference
UTC+9:00
UTC±14:00
Status
Adjust time
9-8-5. SYSTEM - Pulse
Parameter
Default value
Setting values
Note
Use
OFF
OFF/ON
Mode
Pulse count
Pulse count/rpm
Edge
UP
UP/DOWN
Pulses per revolution
1.0
ASCII
Unit substitution
9. Settings