52
10-6-2. WX sync
Preparation
1
Use a synchronization cable to connect the
SYNC OUT connector of the WX-7000 to the
VR-24/WX SYNC connector of the VR-24.
The VR-24 will operate as the slave unit.
2
Turn the VR-24 on.
3
Set the VR-24 Synchronization type to “WX sync”.
4
Turn the WX-7000 on.
5
Use the WX-7000 synchronization settings to
conduct a “connection check”.
If there are no connection problems, the “Sync sta-
tus” will be “OK”.
6
Touch the “Adjust time” button to set the
time used by the VR-24 to that used by the
WX-7000.
o
The error is ±1 second.
Recording
When recording operations are conducted with the
WX-7000, the same operations will automatically be
conducted on the VR-24.
NOTE
o
When the following settings are made on the
WX-7000, they will also be made on the VR-24
automatically.
u
Sampling series
u
Sampling frequency
u
Bit depth
o
Event marks can only be set on the WX-7000.
10. SYSTEM settings
10-6-3. LX sync
Preparation
1
Use a synchronization cable to connect the
AQ-VU connector of the LX-110/120 to the
VR-24/WX SYNC connector of the VR-24.
The VR-24 will operate as the slave unit.
2
Turn the VR-24 and LX-110/120 on.
3
Set the VR-24 Synchronization type to “LX sync”.
Recording
1
Press the VR-24 Record button to make it
record ready.
2
Make the LX-110/120 record ready.
3
Start recording with the LX-110/120.
The VR-24 will also start recording automatically.
ATTENTION
o
During LX synchronization, the VR-24 cannot be
switched from recording to record ready. When the
LX-110/120 is switched from recording to record
ready, the VR-24 will stop recording and enter a
stopped state.
o
The time cannot be adjusted automatically. Adjust
the times used by the units manually before
recording.
o
Make sampling settings and related settings
manually.
o
Set the following settings on the LX-110/120 and the
VR-24 to the same values.
u
Sampling series
u
Sampling frequency
u
Bit depth