56
12-1-1-1. Start conditions
See “Recording starting conditions” on page 31 for
details about each setting.
Level trigger
Set the level, UP/DOWN, logic, count and edge con-
ditions for each channel.
External trigger
The options are ON and OFF.
Timeout
If the conditions set to start recording are not met
within a specified time, recording will be forced to
start automatically.
12. TRIGGER settings
12-1-1-1-1. Level trigger
When Use is ON, the setting items are shown.
Logic
Set when there are multiple conditions to determine
whether one or all must be fulfilled.
AND:
The trigger requirements will be judged ful-
filled when all set conditions are met.
OR:
The trigger requirements will be judged ful-
filled when any set condition is met.
Count
Measurement starts when the set count logic is fulfilled.
CH1, CH2, CH3, CH4
Touch the icon for a channel to turn use ON/OFF for it.
Edge
UP:
The trigger requirement will be judged to
be fulfilled when the input value changes
from lower than the set level value to
higher than that value. The trigger require-
ment will not be judged to be fulfilled
if the level already exceeds the set level
when the unit becomes record ready.
DOWN:
The trigger requirement will be judged to
be fulfilled when the input value changes
from higher than the set level value to
lower than that value. The trigger require-
ment will not be judged to be fulfilled if
the level is already lower than the set level
when the unit becomes record ready.
Level (%)
100% is equal to the Range value set on the Channel
settings screen.