Internal circuit
If a short-circuit occurs between pins 1 and 2 of the UPS SIGNAL IN
connector, recording completion procedures will start. Short-circuits
occur due to contact and non-contact (transistor or TTL open
collector).
Do not increase voltage from outside.
Example using
contact signal
Example using transistor
Example using TTL open collector
Ferrite
Beads
ISOLATOR
BUFFER
0.1uF
+5V
22k
5. Connector specifications
6. Basic operation
6-1. RDX cartridges
6-1-1. Handling
RDX cartridges are designed to be tough, but you should take care
to avoid allowing them to be dropped.
In order to assure the accuracy and security of data, please observe
the following precautions.
o
When purchased new, RDX cartridges are NTFS formatted. Format
cartridges with the WX-7000 before using them with this system.
o
When not using a cartridge store it in a protective case.
o
Do not stack RDX cartridges.
o
Avoid dusty or humid environments.
o
Avoid direct sunlight, high and extremely cold temperatures, as
well as extreme temperature changes.
o
Do not force cartridges into the docking station.
If you are having trouble inserting the cartridge, confirm that you
are inserting it with the correct orientation, including the align-
ment of its keyed corner.
o
Read the RDX cartridge operation manuals.
o
Remove the RDX cartridge before transportation.