34
6-7. Data display
When recording or ready to record, bar meters show the input level
of each channel.
Display channels
Monitor channel
Level bar for channel 1
The bar meters are colored by level as follows.
Level (%)
Color
100 – 127
Red
10 – 100
Green
0 – 10
Blue
0 – -10
Blue
-10 – -100
Green
-100 – -127
Red
Channels shown
This shows the ID number of the connected expansion unit and
the number of channels shown.
6-7-1. Setting the number of channels
shown
While pressing and holding the SHIFT button, press the up (
5
) but-
ton to change to 32-channel display.
32-channel display example
While pressing and holding the SHIFT button, press the down (
b
)
button to change to 16-channel display.
16-channel display example
o
You can also change the number of channels shown using the
DISPLAY CH item on the MISC menu.
6. Basic operation
6-7-2. Peak indicators
Peak indicators are shown when ready to record, when recording
and when playing back.
Example
Peak
Peak
o
Peak indicators are reset whenever recording starts from a record
ready state.
o
When recording stops, the bar meters disappear, but the peak
indicators remain.
o
Press the F1 (Peak Clear) button to clear peak indicators.
6-7-3. Monitored channel
The monitored channel's signal is output from the MONITOR OUT
connector.
Unless the MONITOR CHANNEL item is set to OFF on the SYSTEM
screen, the number of the channel currently being monitored is
highlighted yellow below its bar graph.
o
Select the monitored channel area and press and turn the VALUE
knob to change the monitored channel.