6
B
15cm from lateral wall and
C
80cm from the radiation area (front side of the product)
Flammable materials and furniture should not be placed at a distance of 80 cm in
the radiation area (C) of the flame monitoring cover.
This distance can be reduced to 40 cm when the protection panel is placed
between the stove and the materials that are likely to burn.
Minimum distances for flammable materials and furniture are indicated on the
product label and must not be exceeded. If the floor where the stove needs to be
installed is flammable or heat-sensitive, you should place the product on the
ground protection plate (eg marble or glass base).
In this case the minimum dimensions of stove bottom plate (look at drawing)
should be:
D
50cm (front length)
E
30cm (lateral length from the inner edge of the fire chamber cover)
You can order the floor protection plate from seller when you require.
4.2 STOVE INSTALLATION AND CONNECTION
Product installation and assembly should be done according to the user manual
and by an authorized person. Since our central heating stove with solid fuel for a
flat is designed for interior and provide heat to the ambient, it should not be
installed in bathroom, balcony, cellar, woodshed, etc… The distance between stove
and chimney must be close.
Select an appropriate place for the product. The expansion tank, circulation
pump, mechanical thermostat, indicator panel and chimney connection must
be installed as shown in the installation diagram.
4.2.1 Expansion Tank
After the connection of the expansion tank to the suitable place (wall), it must be
securely connected to the 1”pipe(PVC-metal) and must be connected to 1” records
on the stove, to hot - cold return output and to ¾ connection records on the
expansion tank (see assembly diagram)