Storage, shipping and packing 

 Appliance must be packed and stored vertically, as specified on the packing. 

A horizontal storage, even if temporary, will damage  the appliance.  

All damage due to incorrect packing or storage,will not be taken under warranty. 

Tebas rencourages its customers to keep the heat pump packaging (paperboard pack + polys pallet) for 

the duration of the warranty period in case of a need to return the appliance to the factory. 

 

Correct packing and storage position. 

Standards 

CE standard conformity 

Tebas pool heat pumps meet the following standards: 

 

Electromagnetic compatibility: 

 

 

2004/108/EC 

 

Safety requirements for low voltage equipment: 

2006/95/EC 

 

Pressure Equipment: 

 

 

 

97/23/CE 

 

Noise production: 

 

 

 

 

200/14/CE 

 

Harmonized standards: 

 

 

 

NF EN 60335.1,2.40 

 

Electrical connections 

 

French standard installation reference: 

 

NF C 15 100. 

Safety 

Although this product contains all safety requirements, it may still present dangers such as: 

Electrically controlled parts   

Parts moving with automatic start-up (fan) 

Cutting edges (evaporator) 

 In  order  to  avoid  accidents,  prevent  close  access  the  appliance  by    children  and  pets.  Never  cover  the 

appliance whilst in operation and never put your fingers, or other objects inside. 

Never turn on the appliance with any of its panels removed. 

Pressure controller 

Tebas heat pumps are provided with HP pressure controller set at 38 Bar. 

Utilization limits 

To  ensure  the  heat  pump  has  been  correctly  sized,  Tebas  must  has  been  previously  contacted  with  a  selection  file 

(available on demand) in order to validate such selection. 

 

“Inverter”  range  heat  pump  models  are  designed  to  operate  from  -15°C  to  +35°C  C  (5°F  to  95°F)  air  temperature 

using a pool cover. 

If  the  machine  is  used  to  work  with  an  ambient  temperature  below  0°,  particularly  for  high  water  temperatures,  it  is 

advised to add an electrical heater (ask your seller). 

Regarding  product  selection  that  has  not  been  validated  by  Tebas  and  working  outside  the  above  ranges;  Tebas 

dissociates its responsibility regarding any lack of performance. 

Before  installing  the  heat  pump,  you  will  have  checked  that  the  impedance  of  your  swimming  pool  electricity 

power supply shall not be more than 0.042 Ω. 

Summary of Contents for INVERTER S

Page 1: ...Handbook Tebas Inverter 20 1 Angielska docx Inverter...

Page 2: ...on 5 Installation conditions 5 Hydraulic connections 6 Electrical connections 6 Heating priority 7 Utilization 8 Water connection 8 Regulation digital controller 9 Water flow setting 12 Winter setting...

Page 3: ...hours The heat pump referred to in this handbook is designed and built solely for private swimming pool use Tebas dissociates its responsibility if used in any other application This handbook is cons...

Page 4: ...th automatic start up fan Cutting edges evaporator In order to avoid accidents prevent close access the appliance by children and pets Never cover the appliance whilst in operation and never put your...

Page 5: ...t side of the fan on a completely free space Make sure that the discharged air will not be sucked back into the evaporator again Provide enough space to allow access to temperature controller To impro...

Page 6: ...on the floor or the walls so the heat pump will not support the weight of the water inside the plumbing Do not use a clamp or other tool to screw the connections hand screwing is sufficient Electrica...

Page 7: ...y water gas they must be separated by a distance of at least 20 cm 8 Heat pump power supply must be protected by a system in conformity with local laws Heating priority It is possible to connect the w...

Page 8: ...emperature is between 15 and 30 C 50 F and 86 F You can then start up your machine Follow the instructions below in the given order each time you start up the pool heat pump especially at the beginnin...

Page 9: ...the machine manage its power and keep low noise low speed Heats the water up to the desired value 1 C Smart Heating mode machine manage it s power for best efficiency Heats the water up to the desire...

Page 10: ...Adjust the desired value with or and wait a few seconds till it is stored automatically Working information 3 symbols at the left bottom corner indicate the working information First symbol indicate...

Page 11: ...ater flow switch position Contact your seller AL10 AL11 HP error AL15 AL16 Too much temperature difference between water in and water out AL18 Comp Out temp Too high AL17 Low temp protection in coolin...

Page 12: ...2 C by pass setting is correct between 10 and 15 C Abnormal pressure If the pressure is too high or too low it indicates that the water flow circulating inside the heat pump is not correct You need to...

Page 13: ...nds on the exposure of swimming pool to wind sun and the pool environment as well as the heat pump size Maintaining the temperature Once the set temperature is reached you may reduce the filtration pe...

Page 14: ...rmation together with the dimensions of the swimming pool your personal details address telephone number and the description of the failure If this procedure is respected the Tebas technician will be...