4. Remove the protective cover from the 16.4 oz.
disposable supply cylinder (save the protective cover
in order to place it on the cylinder after use).
5. Inspect the 16.4 oz. disposable LP-gas supply cylinder
(especially the threaded connection) for damage, dirt
or debris. Remove any dirt and debris. Replace
cylinder if damaged.
6. Gently thread the 16.4 oz. disposable LP-gas supply
cylinder into the Regulator, making sure not to cross
thread the connection. DO NOT FORCE THE
CYLINDER INTO THE REGULATOR.
7. CAUTION: When installed, the top of the 16.4 oz.
disposable LP-gas supply cylinder must be attached to
the Regulator and the bottom of the cylinder must
rest on the surface supporting the appliance. When
properly installed, the cylinder must rest at an
approximate angle of 45
0
from an upright position
(see Figure 4). This will ensure proper vapor
withdrawal.
8. To disconnect, ensure that the Burner Output Knob
is in the OFF position, unthread the LP-gas cylinder
from the Regulator. Place the protective cover on the
cylinder.
9. Disconnect the Regulator Assembly using the “Quick
Disconnect Instructions” (see figure 5). Place the
protective cover on the appliance connection.
Quick Disconnect Instructions
Procedure
1. To connect, push sleeve of socket, toward the
regulator (See Figure A.)
2. Insert plug (See Figure B.), release sleeve.
3. Push plug until sleeve snaps forward locking plug
in socket (See Figure C), (THIS
AUTOMATICALLY OPENS THE
CONNECTION ALLOWING GAS TO
FLOW).
4. To disconnect, push sleeve back and pull out
plug, (THIS AUTOMATICALLY CLOSES
THE CONNECTION TURNING OFF THE
GAS FLOW).
Gas Leak Test
WARNING:
DO NOT USE OPEN FLAME TO PERFORM
LEAK TEST.
Open flame should not be used in the area around
the Cherokee during this test. This procedure
should be carried out each time the gas connection
is disconnected.
1. Ensure that the Burner Output Knob is in the
OFF position (see Figure 6 on pg. 10).
2. Open the appliance’s gas supply cylinder valve
slowly. Apply heavy soapy water or similar
solution to all connections including those made
at the factory.
1. Ensure that the Burner Output Knob is in the
OFF position (see Figure 6 on pg. 10).
2. Open the appliance’s gas supply cylinder valve
slowly. Apply heavy soapy water or similar
solution to all connections including those made
at the factory
3. Inspect all connections for presence of bubbles. If
bubbles appear, close shut-off valve and tighten
connections. Repeat steps 1 and 2 above until
bubbles cease.
Gas Connection
continued
8
Revised 11/04 -- Z21.89b-2004/CSA 1.18b-2004
Figure 5.
Quick Disconnect Fittings
Summary of Contents for Cherokee CH-10SS
Page 2: ...Cherokee Expanded View...