to cross-thread the connection.
9. To disconnect after use, ensure that the Burner Output
Knob is in the OFF position, close the Cylinder
Valve by turning the Handwheel clockwise until it
stops.
10. Loosen the Coupling Nut by turning it
counterclockwise.
11. Disconnect the hose end of the Regulator Assembly
from the appliance using the “Quick Disconnect
Instructions”. Place the cap on the appliance
connection. Place dust cap on cylinder valve outlet
whenever the cylinder is not in use. Only install the
type of dust cap on the cylinder valve outlet that is
provided with the cylinder valve. Other types of caps
or plugs may result in leakage of propane.
Disposable LP Gas Cylinder Connection
(Type No. 600 connection)
WARNING:
ONLY 16.4 OZ. DISPOSABLE CYLINDERS,
MARKED “PROPANE” OR “LP-GAS” MUST BE USED.
THE LP-GAS SUPPLY CYLINDER MUST BE
DISCONNECTED FROM THE REGULATOR WHEN
THIS OUTDOOR COOKING GAS APPLIANCE IS NOT
IN USE.
CAUTION:
WHEN ATTACHED, THE TOP OF THE 16.4
OZ. DISPOSABLE CYLINDER MUST BE ATTACHED TO
THE REGULATOR AND THE BOTTOM OF THE
CYLINDER MUST REST ON THE SURFACE
SUPPORTING THE APPLIANCE. WHEN PROPERLY
INSTALLED, THE CYLINDER SHOULD REST AT AN
APPROXIMATE ANGLE OF 45
0
FROM AN UPRIGHT
POSITION (SEE FIGURE 4) OR A FULLY UPRIGHT
POSITION (SEE FIGURE 3). THIS WILL ENSURE
PROPER VAPOR WITHDRAWAL.
Procedure for Disposable LP Gas Cylinder
Connection (16.4 oz.)
1. Insure that the Burner Output Knob is in the
OFF position (see Figure 7 on pg. 10).
2. Inspect the Regulator for damage, dirt or
debris. Remove any dirt or debris. Replace
Regulator if damaged.
3. Remove the protective cover from the appliance
connection. Attach the Regulator to the
appliance using the “Quick Disconnect
Instructions” (see Figure 5 on pg. 8).
Gas Connection
continued
7
12"
Figure 2.
LP Gas Cylinder Location
Figure 3.
Disposable Cylinder Attachment
Figure 4.
Disposable Cylinder Location
Summary of Contents for Cherokee CH-10SS
Page 2: ...Cherokee Expanded View...