background image

TEC

AR

T. 950S

InSTAllATIon

Installation 

The 950S chronothermostat is a daily and weekly electronic chronothermostat that permits the 
programming of the temperature of your home every hour of the day, every day of the week.
950S is equipped with a backlight display and a graphic visualisation of the programmed temperature
that can be modified by simple and functional commands that facilitate the programming.
950S avoids wasting energy by activating the heating or air-conditioning system only when needed.

950S can be directly installed on a 3 module recess box or on the wall. In either cases, it is advisable to 
position it at a height of 1,5 meters from the wall, in a dry place, away from draughts and heat sources.

INSTALLATION ONTO PATTRESS BOX 503

After connecting the wiring, fix the BASE PLATE (with the slots of the FLAP at the bottom) directly onto the 
three-gang pattress box utilizing the type “A” screws supplied (Fig. 2). 
Lift the BATTERY COVER and fix the CHRONOTHERMOSTAT UNIT to the BASE PLATE utilizing the type “B” 
screws (Fig. 3).
Complete the installation by lowering the BATTERY COVER.

Digital electronic room chronothermostat

Connection to burner, wall-mounted 
boiler, air conditioning system, spring-
return zone valve.

Connection to zone valve.

NC   C  NO

             

NC

L  N

OPEN

CLOSE

950S

1  2  3

C NO

950S

1  2  3

L  N

U

Fig.1

Fig.2

 A         B         C

Screw and plugs supplied

Pattress box

Flap Slots

Screws “A”

Base

Fig.3

Chronothermostat unit

Battery Cover

Screws “B”

Base

WALL INSTALLATION

After fixing the BASE PLATE (with the slots of the FLAP at the bottom) to the wall using the wall plugs and 
supplied type “C” screws, electrically connect the chronothermostat and fix it to the BASE PLATE using the 
type “B” screws. Complete the installation by lowering the BATTERY COVER.

Battery Cover

Chronothermostat unit

Flap Slots

Screws “B”

Screws “C”

Base

Base

Summary of Contents for 950S

Page 1: ...slots of the FLAP at the bottom directly onto the three gang pattress box utilizing the type A screws supplied Fig 2 Lift the BATTERY COVER and fix the CHRONOTHERMOSTAT UNIT to the BASE PLATE utilizing the type B screws Fig 3 Complete the installation by lowering the BATTERY COVER Digital electronic room chronothermostat Connection to burner wall mounted boiler air conditioning system spring retur...

Page 2: ...for that hour The segment at the top on the right A in Fig 5 in correspondence to the overprinted writing indicates the day to which the programme refers The programmed temperature B in Fig 5 is visualised at the top on the right whilst programming and is identified by the day flashing and the symbol C indicating the C During normal functioning the hour or the ambient temperature are alternately v...

Page 3: ...ized and lighting up the hand symbol Fig 5 Now the 950S chronothermostat behaves like a normal ambience thermostat where the adjustment of the temperature is made by using the C and C keys O and P in Fig 5 The set temperature read on the display remains as long as the chronothermostat is in manual mode press the AUT MAN key to pass to automatic mode Off key The chronothermostat is switched off by ...

Page 4: ...e ambient temperature It also permits the user to exit from the setting programme F Key for scrolling the days whilst programming G Recessed key for adjusting the HOUR MINUTES and DAY H Key for copying the programme of the day visualised to another day of the week I Temperature scale for functioning in WINTER mode INV L Temperature scale for functioning in SUMMER mode EST M Key for increasing the ...