background image

9.1 Operation ............................................................................................32 

9.2 Storage ...............................................................................................32 

9.3 Battery Replace ..................................................................................32 

10. Technical Data...................................................................................33

 

10.1 Electrical specifications ....................................................................33 

10.2 Operating Environment.....................................................................33 

10.3 Typical backup time (Typical values at 25°C in minutes:) ....................33 

10.4 Dimensions and weights ....................................................................34 

11. Communication Port ........................................................................34

 

11.1 RS-232 and USB communication ports............................................34 

11.2 RS-232 port.......................................................................................35 

11.3 USB port ...........................................................................................35 

11.4 Installing a Serial Network Management Card (optional).................35 

12. Software.............................................................................................37

 

Appendix: Rear panel.............................................................................38

 

 

1. Safety and EMC Instructions   

 
 
 
 

1.1 Installation 

 

See installation instructions before connecting to the supply. 

 

Condensation  may occur if the UPS is moved directly from a  cold to a 
warm  environment.  The  UPS  must  be  absolutely  dry  before  being 
installed. Please allow an acclimatization time of at least two hours. 

 

Do not install the UPS near water or in damp environment. 

 

Do  not  install  the  UPS  where  it  would  be  exposed  to  direct  sunlight  or 
near heat. 

 

Do not connect appliances or items of equipment which would overload 
the UPS (e.g. laser printers, etc) to the UPS output. 

 

Place cables in such a way that no one can step on or trip over them.   

 

Assure to connect with the earth reliably. 

 

Assure external battery source must be earthed. 

 

Connect the UPS only to an earthed shockproof socket outlet. 

 

The  building  wiring  socket  outlet  (shockproof  socket  outlet)  must  be 
easily accessible to close to the UPS. 

 

With the installation of the equipment, the sum of the leakage current of 
the UPS and the connected load does not exceed 1,5mA. 

 

Do not block ventilation openings in the UPS’s housing. Ensure the air 
vents  on  the  front  and  rear  of  the  UPS  are  not  blocked.  Allow  at  least 
25cm of space on each side. 

 

UPS  has  provided  earthed  terminal,  in  the  final  installed  system 
configuration,  equipotential  earth  bonding  to  the  external  UPS  battery 
cabinets.   

 

An  appropriate  disconnect  device  as  short-circuit  backup  protection 
should  be  provided  in  the  building  wiring  installation.  Please  see  the 
disconnect device specification in chapter 5.2.   

 

The equipment is powered by more than one source. 

1.1.1 Inspection of Unit 

Inspect the UPS  upon receiving. If the UPS  is  apparently  damaged during 
the

 

shipment, please keep the box and packing material in original form for 

the carrier and notify the carrier and dealer immediately. 

Please  read  carefully  the  following  user  manual  and  the  safety 
instructions before installing the unit or using the unit! 

 

Summary of Contents for AP160N Series 1000VA

Page 1: ...iption 17 5 Connection and Operation 19 5 1 Inspection 19 5 2 Connection 19 5 3 Battery charge 21 5 4 Turn on the UPS 21 5 5 Test function 21 5 6 Turn off the UPS 22 5 7 Audible alarm mute function 22...

Page 2: ...ssure to connect with the earth reliably Assure external battery source must be earthed Connect the UPS only to an earthed shockproof socket outlet The building wiring socket outlet shockproof socket...

Page 3: ...the end of the tower 2 Place down the UPS into two stands carefully 3 Pull out the LCD box and rotate it in a clockwise direction to 90 degree and then push it back in the front panel 5 l Rack mount...

Page 4: ...battery terminal A from UPS to EBM terminal B shown as below Users need to remove the small gate C on side of the front panel to allow the outlet wire of the EBM to pass through the gate and then reas...

Page 5: ...the gate and then reassemble front panel B C A D E 9 Note Three or more EBMs can be connected to the UPS in the same way as shown above Note After connect the EBMs please do not forget to set the num...

Page 6: ...alified maintenance personnel 1 3 1 UPS and Battery Care For the best preventive maintenance keep the area around the UPS clean and dust free If the atmosphere is very dusty clean the outside of the s...

Page 7: ...ake on off the load To test batteries 1 Connect the UPS to utility power for at least 48 hours to charge the batteries 2 Press and hold the I button 1 second to start the battery test on line mode or...

Page 8: ...D IEC EN 61000 4 2 Level 3 RS IEC EN 61000 4 3 Level 3 EFT IEC EN 61000 4 4 Level 4 SURGE IEC EN 61000 4 5 Level 4 CS IEC EN 61000 4 6 Level 3 MS IEC EN 61000 4 8 Level 3 Voltage Dips IEC EN 61000 4 1...

Page 9: ...KS Extended backup time 17 4 Panel Description The Display Panel Switch Function ON Button Turn on UPS system By pressing the ON Button I the UPS system is turned on Deactivate acoustic alarm By press...

Page 10: ...orm the transport agency immediately should you find signs of damage Please keep the packaging in a safe place for future use Note Please ensure that the incoming feeder is isolated and secured to pre...

Page 11: ...ed 5 4 Turn on the UPS 1 With utility power connecting Press I button continuously for more than 1 second to turn on the UPS the UPS will get into the inverter mode the LCD screen will indicate the st...

Page 12: ...will cause abnormality or permanent damage 2 One hard wiring type battery terminal on the rear panel is used for connecting the battery pack 3 The battery connection procedure is very important Any i...

Page 13: ...nominal power capacity 25 Note Please follow the following steps to connect the generator l Activate the generator and wait until the operation is stable before supplying power of the generator to th...

Page 14: ...hile the utility power is in normal range so the high efficiency could be gained in the ECO mode Once the mains is loss or abnormal the UPS would transfer to battery mode and the load is supplied cont...

Page 15: ...for more than 10 seconds the setting mode exit automatically The output frequency string OPF Bypass status string bYPA operating mode string MOdE Battery string bSTR Load segment string LS1 and LS2 wo...

Page 16: ...battery voltage is normal and the mains is normal charge automatically again Battery low Battery voltage is low When audible alarm sounding every second battery is almost empty 31 Charge fail The cha...

Page 17: ...d start the UPS If it needs to replace the batteries while the UPS is running make sure the UPS would not shut down during the replacement If there is a battery breaker then turn it off first Disconne...

Page 18: ...a computer connect one end of the serial communication cable that comes with the UPS to the RS 232 port on the UPS Connect the other end of the serial cable to the RS 232 port on a computer The cable...

Page 19: ...er WinPower is a brand new UPS monitoring software which provides user friendly interface to monitor and control your UPS This unique software provides safely auto shutdown for multi computer systems...

Page 20: ...1 AC Output 2 EPO Dry input Communication Port 3 USB Port 4 AC Input 5 Dry out 6 SNMP slot 7 RS232 8 Modem Network Surge Protection 9 Earth Line connection 39 1 1 3K Standard model rear panel 3K KS mo...