6-41
EM18-33012
6. DIAG. TEST OPERATION
(Revision Date Feb. 07, ’97)
6.4 TEST PRINT MODE
6.4 TEST PRINT MODE
Test print mode contains normal test print and process test print.
6.4.1
Normal Test Print
Five kinds of test prints are provided in the test print mode. When performing the test print, 7
parameters should be set. The default parameter at power on is as below:
•
ISSUE COUNT
: 1
•
PRINT SPEED
: 5 inch/sec.
•
SENSOR
: Transmissive sensor
•
RIBBON
: Transmissive ribbon
•
TYPE
: Batch (without cut)
•
LABEL LENGTH : 76 mm
•
PAPER FEED
: Feed
Operating procedure for the test mode is provided below.
Power off
Turn on the power while
holding down the [FEED]
key and [PAUSE] key.
Press the [FEED] key twice.
Press the [PAUSE] key.
Press the [FEED] key
and [RESTART] key at
the same time.
Set the print count
Select "Print Condition"
by pressing the
[PAUSE] key.
Press the
[FEED] key or
[RESTART]
key.
(See NOTE 1.)
Press the
[RESTART]
key.
Continued
on section
6.4.2
Process
Test Print.
ISSUE COUNT
< 1
D I A G N O S T I C
V 1 . O A
>
< 3
T E S T
P R I N T
>
P R
N T
C O N D I T I O N
I
I S
U E
C O U N T
1
S
From C on
the next page.
To be continued on
B of the next page.
To A .
PRINT SPEED
SENSOR
RIBBON
TYPE
LABEL LENGTH
PAPER FEED