6-31
EM18-33017
6. DIAG. TEST OPERATION
NOTE:
When the status type 1 is selected, the printer will send (00H) in response to the status
request command sent from the PC while a label stays at the strip sensor (when idling,
after feeding, or all printing finished).
When the status type 2 is selected, the printer will send (05H) in response to the status
request command sent from the PC while a label stays at the strip sensor (when idling,
after feeding, or all printing finished.)
If the status request command is sent during printing, the printer will always send (05H)
regardless of the setting.
6.3 PARAMETER SETTING MODE
NOTES:
1.
Holding the [FEED] key or [RESTART] key down for more than 0.5 seconds
enables a fast forward.
2.
Max. fine adjustment -15 steps = Key fine adjustment value (-15 steps) + PC fine
adjustment value (-15 steps)
When the value reaches the maximum, the value remains unchanged even if the
subsequent fine adjustment is performed.
3.
A changed motor voltage value is stored in memory by pressing the [PAUSE] key.
4.
One step corresponds to 5% of the standard voltage and up to 75% of the voltage
can be decreased.
6.3.11 Strip Wait Status Setting
Power off
Turn on the power while
holding down the [FEED]
key and [PAUSE] key.
< 1
D I A G N O S T I C
V 1 . O A
>
Press the [FEED] key.
< 2
P A R A M E T E R
S E T
>
Press the [PAUSE] key thirteen times.
Press the [FEED] key or
[RESTART] key to select
the strip wait status.
• [FEED] key
Status type 2: A strip wait status is sent.
Press the [FEED] key
and [RESTART] key
at the same time.
Press the [PAUSE] key.
(See NOTE 1.)
• [RESTART] key
Status type1: A strip wait status is
not sent.
S T
T U S
T Y P E
+ 0
A