6-44
EM18-33017
6. DIAG. TEST OPERATION
Press the [PAUSE] key.
Press the [PAUSE] key.
Select the test print from
those at the right by
pressing the [FEED] key
or [RESTART] key.
Press the [FEED] key
and [RESTART] key at
the same time.
A designated number of
test prints are issued when
pressing the [PAUSE] key.
(See NOTE 8.)
From
B
of the preceding page.
SLANT LINE (1 DOT)
SLANT LINE (3 DOT)
CHARACTERS
BAR CODE
NON-PRINTING
FACTORY TEST PATTERN
AUTO PRINT (TRANS.) :
Process test print/Transmissive sensor
AUTO PRINT (REFLECT.) :
Process test print/Reflective sensor
From
A
of the
preceding page.
NOTES:
1.
When there is no change to the print condition, select one of the test print options
to issue the test print.
2.
Holding the [FEED] key or [RESTART] key down for more than 0.5 seconds
enables a fast forward.
3.
A selected print condition is activated when the [PAUSE] key is pressed.
4.
When the feed gap sensor is selected, the gap between labels becomes 3mm long.
5.
Non-transmissive (NON TRANS.) ribbon cannot be used so the ribbon type must
be set to transmissive (TRANS.) ribbon or no ribbon.
6.
A label size greater than the image buffer length cannot be designated. The image
buffer length differs according to memory size. If designated, the printer prints in
the image buffer, or the printer stops because of an error.
(Revision Date: Jul. 23, 2002)
6.4 TEST PRINT MODE