- 134 -
EO3-11070
MA-1650-4 SERIES
LINK-PLU TABLE PROGRAMMING (Submode 25)
This submode programs Link-PLU Tables and their respective Sub-link PLUs. When a PLU is programmed with
a Link-PLU Table No. (Address 10 of the PLU TABLE PROGRAMMING operation), an entry of the PLU will
automatically enter the Sub-link PLU that is programmed in the Link-PLU Table No. Refer to the “Link-PLU Table
No.” description in the PLU TABLE PROGRAMMING, Submode 4, as to details of PLU-to-PLU linkage.
Programming
CONDITION
Any time outside a sale
OPERATION
Mode Lock: SET
25 [X]
|Link-PLU Table No.| [ST]
|Sub-link PLU Code| [#]
[AT/TL]
Repeat for other tables.
➤
➤
➤
➤
➤
1 to 99 (Enter the No.
pro-grammed in the
Head-link PLU item in
Submode 4.)
*
6 or 13 digits (Enter the code
of the PLU to be auto-entered
when the Head-link PLU is
entered in a sale.)
* (For sequentially programming
tables, the Table No. specifica-
tion can be skipped.)
➤
Barcode Scanning
ex.)
To set the following Link-PLU Table and its Sub-link PLU:
Link-PLU Table No.
Sub-link PLU Code
1
101301
Mode Lock: SET, 25 [X]
1 [ST] 101301 [PLU] [AT/TL]
TEC STORE
1343 PEACH DRIVE
PHONE: 87-6437
Open 8:00am to 7:00pm
Closed: every Wednesday
11-14-1994 MON #1
P25
#01 101301
0055
NOTE:
In this example, Link-PLU Table No. has already been set in PLU 90601 (Coke Small-B) and PLU 90701
(7-up Small-B) as Head-link items in the PLU PROGRAMMING operation, Submode 4. The Sub-link
PLU 101301 here has been programmed as a bottle-deposit PLU (Small-Btl Depo) in the same
submode.