- 11 -
EO3-11084
MA-1350-1 SERIES
All Memory Clear
If the register becomes completely inoperative due to battery discharge or malfunction of the program
memory, the All Memory Clear operation must be carried out. When an All Memory Clear is operated, all
the memory contents that have been stored in the RAM will be cleared (i.e., the programmed data and the
sales data). Along with the clearing process, the designated zero-amount format is set and “Initial Data” and
“Initial Status” for respective programming items are automatically set.
Warning:
This clear operation deletes all programmed data and sales data stored in the register’s
memory. (i.e., the register goes back to initial status.)
Operating Procedure
Condition:
Any time, outside or during any operation sequence
Operation:
Use the S Key to turn the
Control Lock to “BLIND”.
Depress the following Numeric Key according to the display and print format for zero amount and
the nation where the register is used:
NOTE:
When an All Memory Clear is operated, the condition “after all sales data reset” is obtained, just as
“Status Clear” or “Sales Memory Clear”. Therefore, no Reset Reports need to be taken for starting
any programming operation.
Numeric Key
Zero-amount
Format
Version Code
(Nation)
0 . 0 0
. 0
IT (Italy)
US (The United
States and Canada)
1
9
All Memory Clear Symbol
Receipt Consecutive No. is reset
to 0001.
(Date and Time remain unreset.)
Depress the
key.
An All Memory Clear receipt is issued.
AT/TL
Z
REG
X
SET
-
OFF
(BLIND)
MGR
3
9
TEC STORE
1343 PEACH DRIVE
PHONE: 87-6437
Open 8:00am to 7:00pm
Closed: every Wednesday
11-28-1997 #0
RAM-C
0001 10:25TM