Page 1: ...TECE FLUSHING TECHNOLOGY Sanitary systems TECHNICAL GUIDELINES ...

Page 2: ...Flushing technology 6 2 ...

Page 3: ...anical U 1 urinal flush valve housing 6 14 Installing the electronic U 1 urinal flush valve housing 6 V version 6 15 Installing the electronic urinal flush valve 230 V 12 V mains version 6 16 Programming the urinal infrared electronics 6 18 Urinal flush plates for the new U 1 urinal flush valve 6 19 U 2 TECEfilo urinal flush valve 6 20 Bare wall mounting and installation 6 21 Installing the wall m...

Page 4: ...tant plastic and is insulated to prevent condensation A2 drain valve A2 drain valve has been installed in the TECE cistern since the middle of 2009 Zugstange kleine Menge pull rod for small flush volume Zugstange große Menge pull rod for large flush volume Verstellschieber zur Mengeneinstellung adjustment slide for flush volumes Fußdichtung gasket A2 drain valve important components Dual flush tec...

Page 5: ...pressure Grey 32 mm diameter approx 85 flush pressure Black 30 mm diameter approx 75 flush pressure White 28 mm diameter approx 65 flush pressure Reducing the flush pressure The throttle set can be used to reduce the flush pressure if water sprays out of the ceramic To control the flushing pressure a throttle with a smaller internal diameter can be used Increasing the flushing pressure If a toilet...

Page 6: ...rsion set 9820223 scope of delivery The TECE cistern drain valve can be replaced easily The old A1 drain valve should be disposed of together with the associated valve seat and seal When replacing an old A1 drain valve with a new A2 one care must be taken to ensure that the operating lever is also replaced F 10 filling valve The F 10 replacement filling valve order number 9820353 universally fits ...

Page 7: ...he overflow of the drain valve and the top mark in the cistern see diagram Cleaning the filling valve A B The inlet component A or the membrane of the pilot valve B can be cleaned if they become dirty due to polluted water To do this remove the parts and simply hold them under running water If necessary you can obtain replacement parts for the filling valve with order numbers 9820382 valve lever s...

Page 8: ...protection If the seal is intact at the fine installation stage the inner workings of the cistern are intact and free of contamination The connection pipe must be well flushed out during com missioning of the concealed cistern To do this the hose can be lead out of the cistern towards the outside After being flushed out the reinforced hose can be screwed to the filling valve without the need for a...

Page 9: ...sh plates TECElux Mini TECEsquare II metal TECEsquare glass TECEloop plastic TECEloop glass TECEplanus TECEnow TECEambia TECEbase Toilet flush handle The toilet flush plates shown here only give an overview of the available product range See the whole range online at www tece de There you can also find a flush plate config urator which allows you to select the material and colour for the buttons a...

Page 10: ...ending on mains pressure and flush time Durchfluss flow in l s Druck pressure in bar 0 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 0 1 2 3 4 5 6 0 58 Flow diagram of urinal electronics Example Mains pressure 3 bar Flushing flow 0 58 l s Flush time e g 3 5 s Flush volume approx 2 litres The flush housing contains the inlet flow control this is adjusted using an Allen key 3 mm A 90 anti clockwise turn close...

Page 11: ...n the battery version have one connec tion to a battery connector with white marking and one to an electronic cartridge connector with black marking Urinal electronics 6 V battery version Power is supplied by a 6 V battery type 2 CR 5 Lithium 6 V Based on a service life of two years the battery lasts for 220 000 flushes or approx 300 flushes day When the voltage drops to 5 4 V the voltage for oper...

Page 12: ...rallel and the connection cable between the trans former and the furthest electronic unit can be a maximum of 10 m long Schematic diagram of a series installation of 5 urinal electronic units It is recommended that only TECE original products are used for the installation Make sure that the polarity is cor rect when connecting the cables Technical data urinal infrared electronics 230 V 12 V mains ...

Page 13: ...ally identical Cut the bare wall protection flush against the wall and remove it together with the polystyrene support Sufficiently flush out the pipe Observe the following When performing the pressure test the inlet flow control of the flush valve must be set to free flow Before mounting the cartridge ensure that the inlet flow control is closed so that no water can leak out during assembly Close...

Page 14: ... corresponds to a flush volume of 1 litre the second to 2 litres and the third slot to a flush volume of 4 litres Without a retaining ring the flush valve will flush a volume of 6 8 litres Screw in the mechanical cartridge Screw in the actuating rods as described above e g for the TECEambia distance to wall surface 10 mm and screw on the counter nut to prevent them from turning Open the inlet flow...

Page 15: ...the diagram the position also depends on the installation situation of the flush valve housing Horizontal housing shut off on the left electronics on the right vertical housing shut off at the top electronics at the bottom If the cartridge is installed incorrectly the function may operate to start with however malfunctions will occur after a while Open the inlet flow control Screw the support fram...

Page 16: ...nd unscrew the fastening screws on the bare wall protection Install the electric cartridge do not insert with tool and tighten the screws by hand Note It is particularly important when installing the electronic cartridge to place it in the correct position As can be seen on the right hand side of the diagram the position also depends on the installation situation of the flush valve housing Horizon...

Page 17: ...stening screw on the flush valve housing see details and screw the support frame onto the urinal flush valve housing Connect the electronics to the mains and to the cartridge Finally install the flush plate cover and mount the van dal resistant screw supplied ...

Page 18: ...Desired side effect The pre flush stimulates the urge to urinate Pause function optional The volume of water is automatically reduced if the urinal is flushed at intervals of less than two minutes A clean ing flush takes place 45 minutes after the last water sav ing flush Variable flush time Duration 2 10 seconds The flush volume can be adapted to requirements throughout the flush time Distance Th...

Page 19: ...al TECEloop plastic TECEloop glass TECEplanus TECEnow TECEambia The urinal flush plates shown here only give an overview of the available product range See the whole range online at www tece de All urinal flush plates are shown in this overview For more information on TECE push plates refer to the Flush plates technical guidelines ...

Page 20: ...her with the TECE urinal module The transformer is already integrated into the two shell elements which means that it is suitable for direct 230 V connection U 2 TECEbox urinal flush valve housing for brick wall structure 9370040 Compatible with the 230 V mains and the 7 2 V battery variants The transformer for 230 V mains operation is already integrated 210 80 200 130 min 83 TECEprofil urinal mod...

Page 21: ... different trades carrying out the assembly work Therefore the transformer can be directly connected with a 230 V cable 2 3 It is also possible to loop the connection through fig 3 4 R 1 2 To connect the pipe hold the connection housing as shown in fig 4 Installing the wall mounted TECEfilo urinal flush plate 230 V 12 V 1 Cut the thin surface with a cutter knife 2 Use a saw to cut the corner areas...

Page 22: ...ing a flat head screwdriver In the free flow setting fig 3 the shut off slot is parallel with the housing and in the closed setting fig 4 it is at right angles to the housing 5 30 Loosen and remove the flush pipe elbow 6 Make sure that the connection piece is fitted with a seal This seal can be greased if necessary 7 8 30 22 Insert the flusher and close it with the union nut 9 Connect the transfor...

Page 23: ...lve hous ing 12 Connect the plug in connection for the infrared sensor on the cover plate 13 Mount the cover 14 Hook in the bottom of the cover panel 15 The top of the anti theft device must be detached for the installation 16 Mount the anti theft device from the top of the cover using a Philips screwdriver ...

Page 24: ...ey into the notches on the underside of the flush plate The steps for installing the TECEfilo urinal electronics with the 7 2 V battery variant are virtually the same Installing the flush mounted TECEfilo urinal flush plate 230 12 V 1 2 To facilitate installation we recommend shortening the bare wall protection to the correct size already when mounting the flush mounted installation frame If this ...

Page 25: ...ow setting fig 3 the shut off slot is parallel with the housing and in the closed setting fig 4 it is at right angles to the housing 5 30 Loosen and remove the flush pipe elbow 6 Make sure that the connection piece is fitted with a seal This seal can be greased if necessary 7 8 30 22 Insert the flusher and close it with the union nut 9 Connect the transformer s plug in connection 10 Open the inlet...

Page 26: ...the flush mounted installation leave out the anti theft device For the flush mounted installation the cover should always be removed using the bow type handles 13 Connect the plug in connection for the infrared sensor on the cover plate 14 Mount the cover 15 Hook in the bottom of the cover panel 16 Press the cover into the mounting support TECE flushing technology U 2 TECEfilo urinal flush valve ...

Page 27: ...ilure the last settings saved are retained Each configurable setting is assigned a position on the remote control Position Function 1 Pause function off 2 Pause function on 3 Flush time 1 s 4 Flush time 2 s 5 Flush time 3 s 6 Flush time 4 s 7 Flush time 5 s 8 Flush time 6 s 9 Flush time 7 s 10 Flush time 8 s 11 Flush time 9 s 12 Flush time 10 s 13 Pre rinsing off 14 Pre rinsing 0 5 s 15 Pre rinsin...

Page 28: ...bar Flow rate l s Example Mains pressure 4 bar Flow rate 0 44 l s with 5 s flush ing time 2 2 l Adjustable functions Pause function stadium function When the pause function is activated the flushing time is automatically reduced to one second following repeated flushes in short succession less than two minutes 45 minutes after the last economy flush a standard flush is activated Cleaning function ...

Page 29: ... utmost care The correctness of the data presented cannot be guaranteed however TECE assumes no liability for damages resulting from the use of this information Text and images are protected by copyright law Copyright 2018 TECE GmbH Hollefeldstraße 57 48282 Emsdetten Germany ...

Page 30: ...TECE GmbH P 49 25 72 9 28 999 international business tece com www tece com More information on www tece com 04 2018 ...