11
2.
ZONES
This submenu enables the user to configure operation parameters for particular zones
.
REGISTRATION
This function enables the user to register the C-8r, C-mini or CL-mini sensor or the R-8b, R-8bw regulators.
It is also possible to register the C-8f floor sensor as a zone sensor. As a consequence, the zone control will be based on
floor temperature.
2.1.
ON
Once the sensor has been registered in a given zone, it will be used by the L-4 controller. The user may activate the
sensor by selecting <ON>.
2.2.
TYPE OF SENSOR
This option enables the user to choose between wired and wireless sensor
(it concerns zones 1-4).
2.3.
FLOOR HEATING
Registration – to register the floor sensor C-8f in a given zone, first register the zone sensor, then select
<Registration> in the the L-4 controller and press the communication button on the selected C-8f sensor. After
successful registration, an appropriate message will appear on the display of the L-4 controller and the control
light on the C-8f sensor will blink twice.
Type of sensor – this option enables the user to choose between wired sensor (zone 1-4) and wireless sensor
(zone 1-8).
2.4.
ZONE VALVE
This function enables the user to choose the type of valve between wired ST-230/2 (zone 1-4) and wireless STT-230V/2
controlled via a wireless module MW-1-230V (zone 1-8). If <Wireless> is selected, it is necessary to register the module.
Zones
1
-8
ON
Type of sensors
Floor heating
Zone valve
Pre-set temperature
Operation mode
Hysteresis
Calibration
Actuators
Window sensors