15
- register a wireless additional pump contact (executive module)
- switch off a given zone
- set up activation delay (if the temperature in a given zone is too low, the contact will be enabled after the delay time).
6.
VOLTAGE-FREE CONTACT
This function enables the user to register wireless module MW-1. Once the module has been registered, the user may
enable the contact, remove it and view the radio signal strength.
The voltage-free contact is activated if the temperature in any zone is too low.
NOTE
Selecting ‘Built-in contact’ option in Voltage-free contact function results in switching from operating the built-in
voltage-free contact (by default configured to control the floor pump) to operating the heating device!
7.
ADDITIONAL CONTACTS
Follow these steps to register the MW-1 module:
Select registration option in the L-4 WiFi controller
Press the registration button in the MW-1 module
NOTE
It is possible to register the maximum of 8 MW-1 modules.
Once the module has been registered, it is possible to choose the operation mode of the contact: weekly control or the
control of the zones to which the additional contact is assigned. The additional contact options enable the user to view
the radio signal strength and remove a module from the controller memory.
If you select Zones as the operation mode, it is necessary to select the zones to which the additional contact should be
assigned.
8.
FITTER'S MENU
8.1.
INTERNET MODULE
WiFi network selection
After entering this submenu, the controller displays a list of available networks. After selecting the network which we
want to connect with, confirm by pressing the MENU button. If the network is secured, a password is required. Use the +
and - buttons to select subsequent letters of the password. Press EXIT to complete.
Network configuration
The standard network configuration is performed automatically. However, it is possible to do it manually using the options
of this submenu: DHCP, IP address, Subnet mask, Gateway address, DNS address and MAC address.
Registration
Select this option to generate a code necessary to register the controller at emodul.eu.