background image

 

 

I.

 

SAFETY 

 

Before  using  the  device  for  the  first  time  the  user  should  read  the  following  regulations  carefully.  Not  obeying  the  rules 
included in this manual may lead to personal injuries or controller damage. The user’s manual should be stored in a safe place 
for further reference. In order to avoid accidents and errors it should be ensured that every person using the device has 
familiarized themselves with the principle of operation as well as security functions of the controller. If the device is to  be 
sold or put in a different place, make sure that the user’s manual is there with the device so that any potential user has access 
to essential information about the device.  

The manufacturer does not accept responsibility for any injuries or damage resulting from negligence; therefore, users are 
obliged to take the necessary safety measures listed in this manual to protect their lives and property. 

 

  WARNING 

 

High voltage! Make sure the controller is disconnected from the mains before performing any activities involving 
the power supply (plugging cables, installing the device etc.). 

 

The device should be installed by a qualified electrician. 

 

Before  starting  the  controller,  the  user  shoud  measure  earthing  resistance  of  the  electric  motors  as  well  as  the 
insulation resistance of the cables. 

 

The controller should not be operated by children. 

 

  NOTE 

 

The device may be damaged if struck by a lightning. Make sure the plug is disconnected from the power supply 
during storm. 

 

Any use other than specified by the manufacturer is forbidden. 

 

Before and during the heating season, the controller should be checked for condition of its cables. The user should 
also check if the controller is properly mounted and clean it if dusty or dirty. 
 
 
 

Changes in the merchandise described in the manual may have been introduced subsequent to its completion on 07.01.2021. 
The manufacturer retains the right to introduce changes to the structure. The illustrations may include additional equipment. 
Print technology may result in differences in colours shown. 

 

 

We are committed to protecting the environment. Manufacturing electronic devices imposes 
an obligation of providing for environmentally safe disposal of used electronic components and 
devices. Hence, we have been entered into a register kept by the Inspection For Environmental 
Protection.  The  crossed-out  bin  symbol  on  a  product  means  that  the  product  may  not  be 
disposed  of  to  household  waste  containers.  Recycling  of  wastes  helps  to  protect  the 
environment. The user is obliged to transfer their used equipment to a collection point where 
all electric and electronic components will be recycled. 

 

 

Summary of Contents for EU-M-9t

Page 1: ...1 EU M 9t...

Page 2: ...tings 11 4 Screen settings 11 5 Screensaver 11 6 Theme 11 7 Sound 11 8 Registration 11 9 Module Wi Fi 11 10 Protections 12 11 Factory settings 12 12 Software version 12 VI How to control the heatingsy...

Page 3: ...stance of the electric motors as well as the insulation resistance of the cables The controller should not be operated by children NOTE The device may be damaged if struck by a lightning Make sure the...

Page 4: ...ity of controlling the operation of main controllers and thermostatic actuators room regulators wired temperature sensors EU R 9b EU R 9z EU R 9s EU C 7p and wireless temperature sensors EU C 8r EU R...

Page 5: ...ntroller switch off the power supply and prevent it from being accidentally switched on WARNING Incorrect connection of cables may lead to controller damage In order to mount the panel on the wall scr...

Page 6: ...6 In order to mount another control panel connect a four core cable to appropriate ports using the diagram below NOTE Make sure the wires are connected properly...

Page 7: ...7...

Page 8: ...Enter controller menu 2 WiFi signal strength 3 Question mark icon tap here to open up a screen with current external temperature contact status and pump status 4 Tab change 5 Current time 6 Zone statu...

Page 9: ...ings of a given zone tap on the zone status The screen will show basic zone editing screen 1 Return to the main screen 2 WiFi signal strength 3 The number of the zone which the displayed information r...

Page 10: ...nking time Select animation Animation duration Screensaver No screensaver Clock Date External temperature Theme 1 3 Sound ON Frequency Registration 1 4 module Wi Fi Disconnect Select Wi Fi network Reg...

Page 11: ...activate deactivated button sounds 8 REGISTRATION This function enables the user to register EU M 9t control panel in EU L 9r external controller In order to register EU M 9t panel follow these steps...

Page 12: ...r 12 SOFTWARE VERSION When this option is selected the display shows the logo of the CH boiler manufacturer and the controller software version VI HOW TO CONTROL THE HEATINGSYSTEM VIA WWW EMODUL EU 1...

Page 13: ...en zone has been interrupted The most common cause is the flat battery which needs replacing Tap on the tile corresponding to a given zone to edit its pre set temperature Screenshot presenting an exam...

Page 14: ...up the schedule selection screen Screenshot presenting weekly schedule choice Two types of weekly schedules are available in EU M 9t controller 1 Local schedule It is a weekly schedule assigned to a...

Page 15: ...The starting point for each program is the pre set temperature value For each program the user may define up to 3 time periods when the temperature will be different from the pre set value The time p...

Page 16: ...TISTIGS TAB Statistics tab enables the user to view the temperature values for different time periods e g 24h a week or a month It is also possible to view the statistics for the previous months 6 SET...

Page 17: ...automatically when communication is established Alarm actuator STT 868 ERROR 0 Flat battery in the actuator Replace the batteries ERROR 1 Some parts have been damaged Call the service staff ERROR 2 N...

Page 18: ...istance too early The valve stroke is too small or the valve dimensions are not typical Actuator current sensor is damaged Low battery level Replace the batteries Call the service staff ERROR 4 No fee...

Page 19: ...y related products EU OJ L 2009 285 10 as amended as well as the regulation by the MINISTRY OF ENTREPRENEURSHIP AND TECHNOLOGY of 24 June 2019 amending the regulation concerning the essential requirem...

Page 20: ...20 Wieprz 15 10 2020...