background image

 

 

III.

 

HOW TO INSTALL THE CONTROLLER 

 
WARNING 
The device should be installed by a qualified electrician. 

 

WARNING 

Risk of fatal electric shock from touching live connections. Before working on the controller switch off the 
power supply and prevent it from being accidentally switched on. 

 

WARNING 

Incorrect connection of cables may lead to controller damage. 

 

In order to mount the panel on the wall, screw the rear part of the housing onto the wall (1) and slide the device into to (2). 
The EU-M-9t panel works with an additional MZ-RS power supply (3) included in the set, mounted near the heating device. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for EU-M-9t

Page 1: ...1 EU M 9t...

Page 2: ...tings 11 4 Screen settings 11 5 Screensaver 11 6 Theme 11 7 Sound 11 8 Registration 11 9 Module Wi Fi 11 10 Protections 12 11 Factory settings 12 12 Software version 12 VI How to control the heatingsy...

Page 3: ...stance of the electric motors as well as the insulation resistance of the cables The controller should not be operated by children NOTE The device may be damaged if struck by a lightning Make sure the...

Page 4: ...ity of controlling the operation of main controllers and thermostatic actuators room regulators wired temperature sensors EU R 9b EU R 9z EU R 9s EU C 7p and wireless temperature sensors EU C 8r EU R...

Page 5: ...ntroller switch off the power supply and prevent it from being accidentally switched on WARNING Incorrect connection of cables may lead to controller damage In order to mount the panel on the wall scr...

Page 6: ...6 In order to mount another control panel connect a four core cable to appropriate ports using the diagram below NOTE Make sure the wires are connected properly...

Page 7: ...7...

Page 8: ...Enter controller menu 2 WiFi signal strength 3 Question mark icon tap here to open up a screen with current external temperature contact status and pump status 4 Tab change 5 Current time 6 Zone statu...

Page 9: ...ings of a given zone tap on the zone status The screen will show basic zone editing screen 1 Return to the main screen 2 WiFi signal strength 3 The number of the zone which the displayed information r...

Page 10: ...nking time Select animation Animation duration Screensaver No screensaver Clock Date External temperature Theme 1 3 Sound ON Frequency Registration 1 4 module Wi Fi Disconnect Select Wi Fi network Reg...

Page 11: ...activate deactivated button sounds 8 REGISTRATION This function enables the user to register EU M 9t control panel in EU L 9r external controller In order to register EU M 9t panel follow these steps...

Page 12: ...r 12 SOFTWARE VERSION When this option is selected the display shows the logo of the CH boiler manufacturer and the controller software version VI HOW TO CONTROL THE HEATINGSYSTEM VIA WWW EMODUL EU 1...

Page 13: ...en zone has been interrupted The most common cause is the flat battery which needs replacing Tap on the tile corresponding to a given zone to edit its pre set temperature Screenshot presenting an exam...

Page 14: ...up the schedule selection screen Screenshot presenting weekly schedule choice Two types of weekly schedules are available in EU M 9t controller 1 Local schedule It is a weekly schedule assigned to a...

Page 15: ...The starting point for each program is the pre set temperature value For each program the user may define up to 3 time periods when the temperature will be different from the pre set value The time p...

Page 16: ...TISTIGS TAB Statistics tab enables the user to view the temperature values for different time periods e g 24h a week or a month It is also possible to view the statistics for the previous months 6 SET...

Page 17: ...automatically when communication is established Alarm actuator STT 868 ERROR 0 Flat battery in the actuator Replace the batteries ERROR 1 Some parts have been damaged Call the service staff ERROR 2 N...

Page 18: ...istance too early The valve stroke is too small or the valve dimensions are not typical Actuator current sensor is damaged Low battery level Replace the batteries Call the service staff ERROR 4 No fee...

Page 19: ...y related products EU OJ L 2009 285 10 as amended as well as the regulation by the MINISTRY OF ENTREPRENEURSHIP AND TECHNOLOGY of 24 June 2019 amending the regulation concerning the essential requirem...

Page 20: ...20 Wieprz 15 10 2020...

Reviews: