Description

 

Room regulators EU-R-9b are intended to be installed in heating zones. 

They send temperature information to EU-L-9 external controller, which 

uses the information to control the thermostatic valves (by opening them 

when the temperature is too low and closing them when the pre-set room 

temperature has been reached). 

Current  temperature  is  displayed  on  the  screen.  It  is  also  possible  to 

change the pre-set temperature in a zone permanently or for a period of 

time (with time limit). 

 

Controller assets:

• 

built-in temperature sensor

• 

wall-mountable cover

• 

possibility of connecting floor sensor

How to use the controller

1. Display - current zone temperature

2. LED - 

flashing

 - pre-set zone temperature has not been reached

             

steady on

 - pre-set temperature has been reached

3. MINUS/PLUS buttons

NOTE

• 

If you press  PLUS and MINUS at the same time, the screen will 

display  current  floor  temperature  (if  the  floor  sensor  has  been 

connected). 

• 

If you hold PLUS and MINUS at the same time, you may open up 

the software version submenu or heating/cooling submenu (HEA/

COO)*. 

*The functions available depend on the main controller version. 

The device should be installed by a qualified person. In order to install the 

regulator correctly, connect the sensor wires properly. 

Mount the EU-R-9b sensor hanger on the wall and next fit the cover.

How to register the room regulator in a 

given zone:

Each room regulator should be registered in a zone. In order to register, 

go to the EU-L-9 controller menu and select Registration in the submenu 

of a given zone (Menu / Zone / Type of sensor / Wired). After selecting 

Registration  icon,  press  and  hold  the  button  at  the  back  of  the  room 

regulator for 4 seconds. 

If  the  registration  process  has  been  completed  successfully,  EU-L-9 

screen displays an appropriate message whereas the room sensor screen 

displays Scs. If the room sensor displays Err, an error has occurred during 

the registration process.  

NOTE

Only one room regulator may be assigned to a zone. 

The following rules must be kept in mind:

- once registered, the regulator cannot be unregistered, but only switched

off in the submenu of a given zone.

- if the user attempts to assign a sensor to the zone to which other sensor

has already been assigned, the first sensor becomes unregistered and it

is replaced by the second one. 

- if the user attempts to assign a sensor which has already been assigned

to a different zone, the sensor is unregistered from the first zone and

registered in the new one. 

It is possible to set individual pre-set temperature value and weekly

schedule for each room regulator assigned to a given zone. 

How to change the pre-set temperature

The  pre-set  zone  temperature  may  be  adjusted  directly  from  EU-R-9b 

room sensor using PLUS and MINUS buttons.

During  controller  inactivity,  the  main  screen  displays  current

zone temperature. After pressing PLUS or MINUS, the current temperature

is replaced with the pre-set temperature (the digits are flashing). Using

PLUS  and  MINUS  the  user  may  adjust  the  pre-set  temperature  value.

After setting desired value wait for 3 seconds – after this time the display

shows  a  panel  to  define  how  long  the  new  setting  should  apply.

Time settings may be adjusted:

-  permanently  –  press  PLUS  button  until  Con  appears  on  the  screen 

(the pre-set value will apply all the time regardless of schedule settings).

- for a specified number of hours – press PLUS or MINUS until the desired

number of hours appears on the screen e.g. 01h (the pre-set value will

apply for a specified period of time; after that the weekly schedule will

apply).

- if the temperature value defined in the weekly schedule settings should

apply, press MINUS until the screen displays OFF.

EU Declaration of conformity

Hereby,  we  declare  under  our  sole  responsibility  that 

EU-R-9b

 

manufactured  by  TECH  STEROWNIKI,  head-quartered  in  Wieprz  Biała 

Droga  31,  34-122  Wieprz,  is  compliant  with  Directive  2014/35/EU  of 

the  European  Parliament  and  of  the  Council  of  26  February  2014  on 

the harmonisation of the laws of Member States relating to the making 

available on the market of electrical equipment designed for use within 

certain  voltage  limits  (EU  OJ  L  96,  of  29.03.2014,  p.  357),  Directive 

2014/30/EU of the European Parliament and of the Council of 26 February 

2014  on  the  harmonisation  of  the  laws  of  Member  States  relating  to 

electromagnetic compatibility (EU OJ L 96 of 29.03.2014, p.79), Directive 

2009/125/EC  establishing  a  framework  for  the  setting  of  ecodesign 

requirements  for  energy-related  products  as  well  as  the  regulation  by 

the  MINISTRY  OF  ENTREPRENEURSHIP  AND  TECHNOLOGY  of  24  June 

2019  amending  the  regulation  concerning  the  essential  requirements 

as regards the restriction of the use of certain hazardous substances in 

electrical and electronic equipment, implementing provisions of Directive 

(EU)  2017/2102  of  the  European  Parliament  and  of  the  Council  of  15 

November  2017  amending  Directive  2011/65/EU  on  the  restriction  of 

the  use  of  certain  hazardous  substances  in  electrical  and  electronic 

equipment (OJ L 305, 21.11.2017, p. 8).

For compliance assessment, harmonized standards were used:

 PN-EN IEC 60730-2-9:2019-06, PN-EN 60730-1:2016-10.

Wieprz, 19.10.2021

Technical data

Room temperature adjustment range........................................5-350C

Power supply .........................................................................5V DC

Power consumption.................................................................0,01W

Measurement error..............................................................+/-0,50C

We  are  committed  to  protecting  the

environment. 

Manufacturing 

electronic

devices imposes an obligation of providing for

environmentally safe disposal of used electronic

components and devices. Hence, we have been

entered into a register kept by the Inspection

For Environmental Protection. The crossed-out

bin symbol on a product means that the product

may  not  be  disposed  of  to  household  waste

containers. Recycling of wastes helps to protect

the environment. The user is obliged to transfer

their  used  equipment  to  a  collection  point

where  all  electric  and  electronic  components.

The place of connecting 

the EU-L-9r controller 

wires 

Communication 

button

2

1

3

Reviews: