Device description

The user operates the device using touch buttons.

NOTE

The  regulator  is  powered  with  batteries  -  it  is  recommended  to 

check  the  batteries  from  time  to  time  and  replace  them  at  least 

once every heating season. 

First start-up

In order for the EU-T-3.1 controller to work properly, it is necessary to 

follow these steps when starting the device for the first time:

1. Insert the batteries - in order to to do it, remove the front cover of 

the controller.

2. Connect the controller to the heating device.

3. If the room regulator will be used to operate the floor heating system, 

connect an additional sensor to the floor sensor connector.

Operation modes

The room regulator may operate in one of the following operation modes: 

• 

Day/night mode 

–  In  this  mode  the  pre-set  temperature  value 

depends  on  the  current  time  of  the  day.  The  user  may  set  different 

temperature values for the daytime and nighttime as well as define the 

exact time of entering day mode and night mode.

In order to activate this mode, press MENU button until one of the mode 

i c o n s 

appears on the main screen. The user may define the pre-

s e t 

temperature and (after tapping on MENU again) the time of 

entering day and night mode.

• 

Manual mode

 

- In this mode, the pre-set temperature is adjusted 

manually from 

the main screen view with the use of these buttons 

. Manual mode is activated after pressing MENU button. Once the 

manual mode has been activated, the previous operation mode enters 

‘’sleep mode’’ until the next pre-programmed temperature change. 

Manual  mode  may  be  deactivated  by  pressing  EXIT  button. 

until a flashing icon 

 appears on the screen. Use 

 or 

 to set the 

time of  night mode activation.

6. HYSTERESIS

  -  Room  temperature  hysteresis  defines  the  pre-set 

temperature tolerance in order to prevent undesired oscillation in case of 

small temperature fluctuation (within the range of 0,2 - 5°C).

Example: 

Pre-set temperature : 23°C, Hysteresis: 1°C 

The  room  regulator  reports  that  the  temperature  is  too  low  when  the 

room temperature drops to 22 °C. 

In  order  to  set  the  hysteresis,  press  MENU  until  a  flashing  icon   
appears on the screen. Use 

 or 

 to set the desired hysteresis 

value. 

7. FLOOR HEATING ON/OFF

 - This function is used to enable (ON) or 

disable (OFF) the underfloor heating, with the use of 

. When the 

underfloor heating is enabled (icon  )  the  user  may  configure  the 

following parameters:

• 

Maximum temperature 

-  in  order  to  set  the  maximum  floor 

temperature,  press  MENU  until  the  floor  heating  icon  appears  on  the 
screen. Next, use 

 or 

to enable the heating, and then use the 

same buttons to set the maximum temperature.

• 

Minimum temperature

  -  in  order  to  set  the  minimum  floor 

temperature,  press  MENU  until  the  floor  heating  icon  appears  on  the 
screen. Next, use 

 or

 to enable the heating, and then use the 

same buttons to set the minimum temperature.

• 

Hysteresis

  -  underfloor  heating  hysteresis  defines  the  tolerance  for 

the maximum and minimum temperature. The settings range is from  

0,2°C to 5 °C.

Main screen description

1. Battery level

2. Maximum/minimum floor temperature - this icon is displayed only 

when the floor sensor is enabled in the controller menu. 

3. Hysteresis

4. Night mode

5. Day mode

6. Manual mode

7. Current time

8. Cooling/heating

9. Current temperature

10. Button lock

11. Pre-set temperature

Controller functions

The  user  navigates  in  the  menu  structure  using  touch  buttons:  EXIT,   

 and MENU. In order to edit particular parameters, press MENU. 

By  pressing  MENU  the  user  may  preview  the  controller  functions.  The 
edited  parameter  is  flashing.  Use  the  buttons 

 to change the 

parameter settings. Press MENU to confirm the changes and move on to 

edit the next parameter.

1. CLOCK

 - In order to set the time, press MENU button until a digital 

clock settings appear at the top of  the screen. The settings concern the 
flashing parameter. Use 

 or 

 to set the hour. Next, press MENU to 

move to the next parameter - minutes.

2. PRE-SET DAY TEMPERATURE

 - In order to define the pre-set day 

temperature, press MENU button until a flashing icon 

 appears on the 

screen. Use 

 or 

 to set the day temperature.

3. DAY FROM...

 - This function enables the user to define the exact time 

of entering the day mode. To configure this parameter, press MENU until 
a flashing icon 

 appears on the screen. Use 

 or 

 to set the time 

of day mode activation. 

4. PRE-SET NIGHT TEMPERATURE

  -  In  order  to  define  the  pre-set 

night temperature, press MENU button until a flashing icon 

 appears 

on the screen. Use 

 or 

 to set the night temperature.

5. NIGHT FROM... 

- This function enables the user to define the exact 

time of entering the night mode. To configure this parameter, press MENU 

If  the  floor  temperature  exceeds  the  maximum  temperature,  the 

underfloor  heating  will  be  disabled.  It  will  be  enabled  only  after  the 

temperature has dropped below the maximum floor temperature minus 

the hysteresis value.

Example:

Maximum floor temperature: 33°C, Hysteresis: 2°C

When the floor temperature reaches  33°C, the underfloor heating will be 

disabled. It will be activated again when the temperature drops to  31°C.

If  the  floor  temperature  drops  below  the  minimum  temperature,  the 

underfloor  heating  will  be  enabled.  It  will  be  disabled    after  the  floor 

temperature has reached the minimum value plus  the hysteresis value

Example: 

Minimum floor temperature: 23°C, Hysteresis: 2°C

When the floor temperature drops to 23°C, the underfloor heating will be 

enabled. It will be disabled when the temperature reaches 25°C.

8. BUTTON LOCK ON/OFF

 - It is possible to activate button lock. In 

order to do it, press the MENU button until the icon  ,  appears  on  the 

screen and select ON. In order to unlock the buttons, 

press and hold 

any button. 

Menu button functions

By holding the MENU button the user may enter particular functions in 

the Menu. 

1. COOLING/HEATING

 - This icon informs about the room heating or 

cooling to reach the pre-set temperature. These messages are displayed 

alternately: cooling or heating.

2. BUILT-IN SENSOR CALIBRATION

 - Calibration should be 

performed while mounting or after it has been used for a long time, if 

the  room  temperature  measured by  the  sensor  differs  from the  actual 

temperature. Calibration setting range is from -9,9 to +9,9 ⁰C with the 

accuracy of 0,1⁰C.

To  calibrate  the  built-in  sensor,  press  the  MENU  button  until  the 
temperature sensor calibration screen appears. Use the buttons  

 or 

  to  set  the  desired  correction.  To  confirm,  press  the  MENU  button 

(confirm and go on to edit the next parameter).

3. FLOOR SENSOR CALIBRATION

  -  Floor  sensor  calibration  (an 

additional  icon  is  displayed: 

  )  should  be  performed  if  the  floor 

temperature measured by the sensor differs from the actual temperature. 

To  calibrate  the  built-in  sensor,  press  the  MENU  button  until  the  floor 
sensor calibration screen appears. Use the buttons 

 or

 to set the 

desired correction. To confirm, press the MENU button  (confirm and go 

on to edit the next parameter). 

4. SOFTWARE VERSION

  -  After  pressing  the  MENU  button  the  user 

may check the software version number. The number is necessary while 

contacting the service staff.

5. DEFAULT SETTINGS

 - This function is used to restore factory 

settings. In order to do it, change the flashing digit 0 to 1.  

100cm

1

2

3

4

5

6

7

8

9

10

11

1

3

5

4

2

1. Display

2. 

EXIT

  –  press  this  button  to  display  the  room  temperature/  floor 

temperature or to disable manual mode. 
3. 

 – press this button to decrease the edited value. 

4. 

 – press this button to increase the edited value. 

5. 

MENU

  –  –  hold  this  button  to  enable  manual  mode  and  to  set 

calibration. Press the MENU button to move on to edit next parameters. 