Individual signals function in 

WIEGAND output

 operating mode is described in 

table 14

W

ie

g

a

n

d

 

Input 1  

Beeper control (0 V active) 

Input 2  

Yellow LED control (0 V active) 

Output 1 (relay) 

Tamper  signaling;  it  follows  the  alarm  state  of  tamper 
sensors (tamper signal = relay switched on)

 3)

 

Table 14: Signal function in WIEGAND operating mode 

Since the 

FW version 2.79

 the reading synchronization of a 

couple of TECHFASS readers 

is  implemented,  enabling  to 

cancel  the  mutual  disturbance

  of  the  modules.  The  reader 

module offers the 

Wiegand data interface

 

synchronization

 in 

MASTER

 mode. 

6.4.3  Wiegand input (entry reader) 

The  module can be  configured  into a  mode  of  controlling the door from both  sides  (

entry 

reader mode

). 

In  the 

entry  reader  mode

  an  identification  at  an  external  reader  connected  via  the 

WIEGAND  interface

  acquires  a 

reason  code  255

;  at  the  same  time  the  reader  module 

operates standardly, the reason codes equal zero. 

When the reader module operates in the entry reader operating mode, the I/O Port (

tab. 6

is used as an output for controlling the entry reader buzzer. 

Since the 

FW version 2.79

 the reading synchronization of a 

couple of TECHFASS readers 

is  implemented,  enabling  to 

cancel  the  mutual  disturbance

  of  the  modules.  The  reader 

module offers the 

Wiegand data interface

 

synchronization

 in 

SLAVE

 mode. 

The 

WIEGAND input

 and 

WIEGAND output

 operating modes are mutually exclusive. 

6.5  Reading synchronization 

Since the 

FW version 2.79

 the reading synchronization of a 

couple of TECHFASS readers 

is  implemented,  enabling  to 

cancel  the  mutual  disturbance

  of  the  modules.  The  reader 

module  offers  to  use  the 

IO  synchronization

  in  both 

MASTER

  and 

SLAVE

  mode.  The 

input/output port 3

 is used as the 

synchronization signal

7  Useful links 

 

Wiring diagrams: 

http://techfass.cz/diagrams-aps-400-en.html

 

 

Program equipment: 

http://techfass.cz/software-and-documentation-en.html

 

Summary of Contents for APS 400 NREM 76

Page 1: ...EM 76 Network reader modules User s guide 2004 2015 TECH FASS s r o V t nsk 1611 19 153 00 Prague Czech Republic www techfass cz techfass techfass cz Date of release 2015 07 23 valid for FW version 2...

Page 2: ...76 BTS and NREM 76 BTW mechanical design 6 4 Installation 7 4 1 Terminals and jumpers 7 4 2 Standard connection recommended not obligatory 4 8 4 3 LED Indicators 8 4 4 Installation instructions 8 5 Se...

Page 3: ...hy it is not recommended to adjust the cable supplied with the original antenna module 2 2 NREM 76E module Complete reader module designed for installation into round installation boxes with inner dia...

Page 4: ...media reading 3 2 Technical features Functional Properties Supply voltage 8 15 VDC Current demand Typical 95 mA Maximal 130 mA Version with keypad N A ID technology typical reading range 3 EM Marin 6...

Page 5: ...IO 22 module for remote output control The WIO 22 remote control WIEGAND relay module is designated for secure output control of APS system reader modules The door open or other functions can be contr...

Page 6: ...emperature 10 C 40 C Humidity Max 75 non condensing Cover According to used installation box Dimensions Suitable for 68 mm installation boxes Table 4 b NREM 76E mechanical design 3 7 NREM 76 BTS and N...

Page 7: ...RS 485 line 11 B cable RS 485 line 12 Relay C 13 Relay NC 14 Relay NO Table 6 Terminal description X1 RS 485 X4 150 Line termination BIAS A Idle state definition A BIAS B Idle state definition B Tabl...

Page 8: ...of the controller 4 4 Installation instructions The reader module uses passive RF ID technology which is sensitive to RF noise sources Noise sources are generally of two types radiating or conducting...

Page 9: ...is required after any change of address setting disconnect and connect the supply voltage again Address jumpers X2 Address 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 X2 1 X2 2 X2 3 X2 4 X2 5 X2 6 Address...

Page 10: ...e available at http www techfass cz files m_aps_400_network_reader_en pdf 6 Reader module functioning 6 1 Operating modes The NREM 76 reader modules are intended for online operating mode on APS 400 s...

Page 11: ...4 1 Standard operating mode This is the module default operating mode The Wiegand interface is used for controlling the WIO 22 module in this configuration When the reader module operates in the stand...

Page 12: ...ode 255 at the same time the reader module operates standardly the reason codes equal zero When the reader module operates in the entry reader operating mode the I O Port tab 6 is used as an output fo...

Reviews: