3.3  Special accessories 

Sp

e

ci

a

a

cce

sso

ri

e

s

 

AEM 12 

51400300 

Antenna module for hidden assembly (no buzzer or LED) 

 

 

 

AEM 12.1 

51400301 

Antenna module for hidden assembly (buzzer present, no LED) 

 

 

 

AEM 13 

51400400 

Antenna module with a ferrite coil for Targha panels 

 

 

 

WIO 22 

51901200 

Remote control module, 2x relay 

 

 

 

3.4  Using WIO 22 module for remote output control 

The 

WIO 22

 remote control 

WIEGAND

 relay module is designated for secure output control 

of APS system reader modules. The door open or other functions can be controlled from 
the module located inside the secure area, while the reader module can be located in the 
non-secure area. 

The  module  is  controller  by 

WIEGAND

  signal  directly from  the  reader  module  working  in 

standard  operating  mode.  The  module  must  be  paired  with  appropriate  reader  module 
before use. 

 

 

Table 3: Special accessories 

Summary of Contents for APS 400 NREM 76

Page 1: ...EM 76 Network reader modules User s guide 2004 2015 TECH FASS s r o V t nsk 1611 19 153 00 Prague Czech Republic www techfass cz techfass techfass cz Date of release 2015 07 23 valid for FW version 2...

Page 2: ...76 BTS and NREM 76 BTW mechanical design 6 4 Installation 7 4 1 Terminals and jumpers 7 4 2 Standard connection recommended not obligatory 4 8 4 3 LED Indicators 8 4 4 Installation instructions 8 5 Se...

Page 3: ...hy it is not recommended to adjust the cable supplied with the original antenna module 2 2 NREM 76E module Complete reader module designed for installation into round installation boxes with inner dia...

Page 4: ...media reading 3 2 Technical features Functional Properties Supply voltage 8 15 VDC Current demand Typical 95 mA Maximal 130 mA Version with keypad N A ID technology typical reading range 3 EM Marin 6...

Page 5: ...IO 22 module for remote output control The WIO 22 remote control WIEGAND relay module is designated for secure output control of APS system reader modules The door open or other functions can be contr...

Page 6: ...emperature 10 C 40 C Humidity Max 75 non condensing Cover According to used installation box Dimensions Suitable for 68 mm installation boxes Table 4 b NREM 76E mechanical design 3 7 NREM 76 BTS and N...

Page 7: ...RS 485 line 11 B cable RS 485 line 12 Relay C 13 Relay NC 14 Relay NO Table 6 Terminal description X1 RS 485 X4 150 Line termination BIAS A Idle state definition A BIAS B Idle state definition B Tabl...

Page 8: ...of the controller 4 4 Installation instructions The reader module uses passive RF ID technology which is sensitive to RF noise sources Noise sources are generally of two types radiating or conducting...

Page 9: ...is required after any change of address setting disconnect and connect the supply voltage again Address jumpers X2 Address 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 X2 1 X2 2 X2 3 X2 4 X2 5 X2 6 Address...

Page 10: ...e available at http www techfass cz files m_aps_400_network_reader_en pdf 6 Reader module functioning 6 1 Operating modes The NREM 76 reader modules are intended for online operating mode on APS 400 s...

Page 11: ...4 1 Standard operating mode This is the module default operating mode The Wiegand interface is used for controlling the WIO 22 module in this configuration When the reader module operates in the stand...

Page 12: ...ode 255 at the same time the reader module operates standardly the reason codes equal zero When the reader module operates in the entry reader operating mode the I O Port tab 6 is used as an output fo...

Reviews: