21
Wiring Diagram
Triple Ultra Clean Oilless Compressor
CHECK
FOR:
1. Broken or loose
wire.
2. Defective pressure
switch.
3. Defective ON/OFF
switch.
4. Excessive voltage
drop across power
lines.
NOTE:
Voltage
should be + or -
10% of rating.
Is there sufficient
voltage at motor
terminals while
motor tries to start?
GO ON TO
THE NEXT
PAGE.
COMPRESSOR
DOES NOT RUN
OR RUNS FOR
ONLY A FEW
SECONDS.
YES
Does head
run with dis-
charge line
disconnected?
NO
Is there suffi-
cient voltage
at disconnect
box?
Blockage in
air line locate
& repair.
YES
Install
Tech West
transformer.
NO
YES
NO
YES
Is there
resistance
rise across
the capaci-
tors?
YES
Replace
defective
capacitors.
NO
Turn power off.
Remove fan guard.
Try turning fan by
hand. If it doesn’t
turn, contact head
may be frozen.
NOTE:
Short capacitor
leads. Check resis-
tance rise. If no
resistance rise,
replace.
208/230v
Summary of Contents for ACO2S
Page 2: ... ...
Page 10: ...8 8 7 6 9 1 2 3 4 5 ULTRA CLEAN OILLESS COMPRESSOR PARTS LIST ...
Page 24: ...22 Maintenance Service Notes ...
Page 25: ...23 Maintenance Service Notes ...
Page 26: ...24 Maintenance Service Notes ...
Page 27: ...25 Maintenance Service Notes ...