7. 

PERIODIC SERVICING

MONTHLY SERVICING

(a) Remove the purge bucket and empty as needed
(b) Crack the drain petcock on the bottom of the storage tank to check for water and drain if needed.
(c) Check moisture indicator to see that it is still “BLUE”.  If it is pink, it is time to service the air dryer.
(d) Check pump-up times of the compressor.
(e) Check intake air supply filters. Replace filters as needed.

YEARLY SERVICING

(a) Repeat all of the monthly servicing.
(b) Replace the alternate air filter. (Part #: TIF-100)
(c) Check the coalescing filter and change if needed. (Part #: CFEO-375)

ELITE SERIES ROCKY COMPRESSOR

INSTALLATION

2

6.

GENERAL SERVICE INFORMATION

For parts and service on Rocky series products contact the nearest authorized Tech West distributor. To
expedite appropriate service, be prepared to provide the unit model number, identification number,
and serial number found on the nameplate located on the front of the unit switch plate.

Component life operating at continuous duty & maximum pressure will shorten the life of the rings
and skirts. It is difficult to predict due to many conditions which directly influence wear. Some of
these conditions may include ambient air temperature, air cleanliness, operating pressure, piston
stroke on the particular model being utilized, duty cycle, maintenance of filters, etc.

Because of these various factors it is appropriate to generalize on component wear life and choose
some conservative estimates for most standard applications.

With these conditions in mind, we recommend the following preventative maintenance schedule.

RECOMMENDED MAINTENANCE

FOR ROCKY MODELS

Minor Service Kits, Piston Cups & Valves, Skirts, Etc.

Major Replacement Kit, Piston & Rod Assemblies

Replace inlet Filter

HOURS

Cont. Duty

Maximum Pressure

8,000 Hours

12,000 Hours

4,000 Hours

TIME

Based on 100%

Duty Cycle

12 months

18 months

6 months

Summary of Contents for ACOR2D1

Page 1: ...Argyle Ave Fresno CA 93727 559 291 1650 800 428 7139 FAX 559 348 9677 TECH WEST INC Manufacturers of Dental Vacuum and Air Systems ELITE SERIES ROCKY COMPRESSOR INSTALLATION AND SERVICE MANUAL Revised...

Page 2: ...ions 4 Elite Series Rocky Start Up 5 Elite Series Rocky Maintenance 6 Elite Series Rocky Compressor Motor Assembly Breakdown 7 8 Coalescing Filter Assembly Breakdown 9 Tank Breakdown 10 Desiccant Drye...

Page 3: ...voltage is not between these values Circuit breaker switches must be 20 amp voltage 2 Local code may require you to provide a quick disconnect safety switch for the compressor 3 See Figure 1 below fo...

Page 4: ...ht otherwise be overlooked Remove cardboard shipping carton b Remove the Oilless Compressor from its shipping skid Inspect the unit for damage Oilless Compressors are shipped bolted to a pallet This p...

Page 5: ...RESSOR INSTALLATION 2 3 CONNECTIONS Figure 2 Dryer Purge Connection Electrical Connection to disconnect and electrical panel 110 v 220 v Alternate Air Connection to fresh air supply Air Out Connection...

Page 6: ...ker from the panel to the ON position c Turn power ON from the toggle switch on the compressor Compressor should run quietly and vibration free The storage tank should start to build pressure d The co...

Page 7: ...dentification number and serial number found on the nameplate located on the front of the unit switch plate Component life operating at continuous duty maximum pressure will shorten the life of the ri...

Page 8: ...9 ROCKY FILTER ASSEMBLY 1 2 3 KEY PART NO DESCRIPTION UNIT 1 CFAO 375 COALESCING FILTER ASSEMBLY 3 8 1 2 CFEO 375 COALESCING FILTER ELEMENT 3 8 1 3 CFBP 375 COALESCING FILTER BOWL 1...

Page 9: ...HR ELITE TANK HANDLE ROCKY 2 5 EPCB ELITE PRECOOLER BRACKET 2 6 CFB P COALESCING FILTER BRACKET 1 7 CFAO 375 COALESCING FILTER ASSEMBLY 1 8 ERPCM ELITE ROCKY PRECOOLER MOUNT 1 9 DPC 1E ELITE PRECOOLER...

Page 10: ...1 4 EDC 100 REPLACEMENT DESSICANT TANK 1 5 MV 250 METERING VALVE 1 6 SN 250 CL STAINLESS STEEL NIPPLE 1 4 3 7 FE 4 6 FLAIR FITTING 1 4 X 3 8 1 8 BV 250 BALL VALVE 1 4 1 9 BT 250 BRASS TEE 1 4 2 10 FPH...

Page 11: ...LVE 1 3 MI 100 MOISTURE INDICATOR 1 4 FA 4 4 1 4 FLARE HOSE FITTING 1 5 POVA 100 POP OFF VALVE 125 PSI ASME 1 6 SSN 375 CL STAINLESS STEEL NIPPLE 3 8 CLOSED 1 7 ATM ALUMINUM TANK MANIFOLD 1 8 FE 4 4 B...

Page 12: ...TOGGLE 13 ELITE ROCKY WIRING DIAGRAMS WIRING DIAGRAM WITH SOUND COVER AND 24v SWITCH 115V...

Page 13: ...SV 115 PURGE VALVE SOLENOID VALVE 115V 1 10 DSV 230 PURGE VALVE SOLENOID VALVE 230V 1 11 CFAO 375 COALESCING FILTER 3 8 1 12 CFEO 375 COALESCING FILTER ELEMENT ONLY 1 13 DPB 100 DRYER PURGE BUCKET 1 1...

Page 14: ...1 16 15 9 10 DUAL ELITE SERIES ROCKY COMPRESSOR 2 2 1 3 4 6 6 7 8 11 12 14 17 18 19 20 21...

Page 15: ...s the moisture indicator pink YES Is intake filter clogged Is there sufficient pressure build up with head discharge line removed YES NO Defective head contact Tech West Note Close shut off valve Pump...

Page 16: ...ONLY A FEW SECONDS YES Does head run with dis charge line disconnected NO Is there suffi cient voltage at disconnect box Blockage in air line locate repair YES Install Tech West transformer NO YES NO...

Page 17: ...Maintenance Service Supplies Service scheduled for Service items needed 22...

Page 18: ...23...

Page 19: ...2625 N Argyle Ave Fresno CA 93727 559 291 1650 800 428 7139 FAX 559 348 9677 TECH WEST INC Manufacturers of Dental Vacuum and Air Systems...

Reviews: